2
No
Module not ready
3
-
Reserved
4
No
Cable Check
5
Yes
6
Yes
7
Yes
8
Yes
Pre Charge
9
-
Reserved
Technology module TM ECC PL ST (6FE1242-6TM20-0BB1)
Manual, 07/2019, A5E43919893B-AA
The module is not ready yet for the next charging
•
process.
The communication module does not report back.
•
Possible causes of the fault: External 24 V supply of
the module is faulty.
If possible, the frequency converter is ramped down in
a controlled manner.
-
External voltage too high
Before the Cable Check phase, a voltage is measured
•
that is greater than the value set in the
"in.evseCfg.maxExtVoltageInVolt" parameter.
This error is vehicle-specific and is automatically
•
acknowledged.
The charging process is canceled.
Target voltage could not be reached
The target current required by the vehicle could not be
•
reached or lies outside the allowed range.
The frequency converter is ramped down in a controlled
manner.
DC leakage current too high
The measured leakage current is higher than the val-
•
ue set by the
"in.evseCfg.cableCheckCurrentInAmpere" parameter.
The frequency converter is ramped down in a controlled
manner.
Voltage could not be ramped down.
The voltage could not be ramped down at the end of
•
the CableCheck phase.
If possible, the frequency converter is shut down in a
controlled manner.
Target voltage could not be reached
The output voltage of the frequency converter
•
"in.values.voltageInVolt lies outside the valid range.
The frequency converter is ramped down in a controlled
manner.
-
Programming
5.6 Error messages
67