Siemens SIMATIC ET 200SP Manual page 69

Technology module tm ecc pl st
Hide thumbs Also See for SIMATIC ET 200SP:
Table of Contents

Advertisement

2
No
Module not ready
3
-
Reserved
4
No
Cable Check
5
Yes
6
Yes
7
Yes
8
Yes
Pre Charge
9
-
Reserved
Technology module TM ECC PL ST (6FE1242-6TM20-0BB1)
Manual, 07/2019, A5E43919893B-AA
The module is not ready yet for the next charging
process.
The communication module does not report back.
Possible causes of the fault: External 24 V supply of
the module is faulty.
If possible, the frequency converter is ramped down in
a controlled manner.
-
External voltage too high
Before the Cable Check phase, a voltage is measured
that is greater than the value set in the
"in.evseCfg.maxExtVoltageInVolt" parameter.
This error is vehicle-specific and is automatically
acknowledged.
The charging process is canceled.
Target voltage could not be reached
The target current required by the vehicle could not be
reached or lies outside the allowed range.
The frequency converter is ramped down in a controlled
manner.
DC leakage current too high
The measured leakage current is higher than the val-
ue set by the
"in.evseCfg.cableCheckCurrentInAmpere" parameter.
The frequency converter is ramped down in a controlled
manner.
Voltage could not be ramped down.
The voltage could not be ramped down at the end of
the CableCheck phase.
If possible, the frequency converter is shut down in a
controlled manner.
Target voltage could not be reached
The output voltage of the frequency converter
"in.values.voltageInVolt lies outside the valid range.
The frequency converter is ramped down in a controlled
manner.
-
Programming
5.6 Error messages
67