Install the Center Rack Control

Machine's Center Boom Function Coils
FIGURE 15.
Locate the center up coil on the machine's hydraulic valve.
1.
Unplug the coil connector from the center up coil.
2.
Install a center rack control boom sense adapter cable (P/N 115-0230-037) to the machine's up coil.
3.
Connect the coil connector to the installed boom sense adapter cable.
4.
Plug the single connectors on the installed boom sense adapter cable to the Center Up harness connectors
5.
on the AutoBoom harness cable (P/N 115-0230-045 or 115-0230-085).
Locate the center down coil on the machine's hydraulic valve.
6.
Unplug the coil connector from the center down coil.
7.
Install a center rack control boom sense adapter cable (P/N 115-0230-037) to the machine's down coil.
8.
Connect the coil connector to the installed boom sense adapter cable.
9.
Plug the single connectors on the installed boom sense adapter cable in the Center Down harness
10.
connectors on the AutoBoom harness cable.
Machine's Unloader Coil
FIGURE 16.
Locate the unloader coil on the machine's hydraulic valve.
11.
Note:
The appearance of the connectors may vary from machine to machine.
Unplug the unloader coil and connect it to the female end of the weatherpack boom sense adapter cable (P/
12.
N 115-0171-558).
Connect the double-ended male end of the weatherpack boom sense adapter cable to the unloader coil.
13.
Connect the single-ended male end of the weatherpack boom sense adapter cable to the female Open
14.
Center connector on the AutoBoom valve harness.