Control Panel
Solution 2000 / 3000
en
Quick Reference Guide

Advertisement

Table of Contents
loading

Summary of Contents for Bosch Solution 3000

  • Page 1 Control Panel Solution 2000 / 3000 Quick Reference Guide...
  • Page 3: Table Of Contents

    Swinger Shutdown Count For Siren 4.7.2 Swinger Shutdown Count For Report Zone Status Programming 4.8.1 STAY Mode 2 Automatically Bypass Zones 4.8.2 Zone Status Reporting Options RF Programming Bosch Security Systems, Inc. Quick Reference Guide 2015.06 | 03 | F.01U.298.027...
  • Page 4 User Code Area Assignment 4.17 Default Options 4.18 RFID Programming 4.18.1 Keyfob RFID 4.18.2 Zone/Device RFID and RF Zone Option 4.18.3 Repeater RFID 4.19 Text Codepad Items 4.19.1 Home Message 2015.06 | 03 | F.01U.298.027 Quick Reference Guide Bosch Security Systems, Inc.
  • Page 5 Control Panel Table of Contents | en 4.19.2 Zone Names 4.19.3 User Names Appendices Connections for EOL Resistors Wiring Diagram Component Overlay Codepad Address Setting Bosch Security Systems, Inc. Quick Reference Guide 2015.06 | 03 | F.01U.298.027...
  • Page 6: Introduction

    Installation Guide that provides detailed information on system options, functions, and programming methods. Throughout this document, the words “control panel ” refer to all control panels covered by this document ( Solution 2000 / Solution 3000 ). Features Solution 2000...
  • Page 7: Programming

    Enter the new data then [*] to save it. Enter [#] to go to the next location. When [Confirm to Save Parameter Changes?] display, press [#] to save parameter changes , exit menu programming and reset system. Bosch Security Systems, Inc. Quick Reference Guide 2015.06 | 03 | F.01U.298.027...
  • Page 8 [497.4] STAY indicator for day alarm [496.4] Digit 3 for codepad duress alarm [498.2] Siren and strobe output in STAY [498.3] Speaker beep volume [491] Country code [112] 2015.06 | 03 | F.01U.298.027 Quick Reference Guide Bosch Security Systems, Inc.
  • Page 9 Swing shutdown Report swing shutdown count [380] Silent zone tamper alarm [498.4] Zone option Unseal RF zone that failed monitor [396.3] Bosch Smart Lockout enable [492.1] Zone pulse count handover enable [494.3] Handover delay in order [494.4] Codepad area [518]...
  • Page 10: Icon Lcd Codepad Programming

    Step back one Location Program new data into Location [Data][*] (Data = 0 to 15) Jump to another Location [Location No.] [#] Table 2.1: Quick Guide to Programming 2015.06 | 03 | F.01U.298.027 Quick Reference Guide Bosch Security Systems, Inc.
  • Page 11: Programming Option Bits

    Copy IUI-SOL-ADAPTER data to the control panel memory Set up domestic dialing format Enable/disable the automatic stepping of locations during programming Display the control panel firmware version number Table 2.3: Installer’s Programming Commands Bosch Security Systems, Inc. Quick Reference Guide 2015.06 | 03 | F.01U.298.027...
  • Page 12: Operating Commands

    Menu Code+[#] AWAY Arm / Disarm Code+[0][1] STAY1 Arm/Disarm Area Or STAY2 Disarm Area 1 Code+[0][2] STAY1 Arm/Disarm Area Or STAY2 Disarm Area 2 Code+[0][1] AWAY Arm/Disarm Area 2015.06 | 03 | F.01U.298.027 Quick Reference Guide Bosch Security Systems, Inc.
  • Page 13 Table 3.1: Operating Commands Access Key: A = All have access (no code required) U = User and Master access (user code required) I = Installer access (Installer code required) Bosch Security Systems, Inc. Quick Reference Guide 2015.06 | 03 | F.01U.298.027...
  • Page 14: Add/Delete Rf Device (Wireless Zones)

    Enter the Installer Code, followed by [0] and the [#] key. Enter the point id of RADION Repeater (822 to 829) you want to delete, followed by the [#] key. 2015.06 | 03 | F.01U.298.027 Quick Reference Guide Bosch Security Systems, Inc.
  • Page 15: Add/Delete Rf Keyfob

    Press the [*] key to delete the RADION Keyfob. Example: To delete existing RADION keyfob 1: Enter your installer code and press [0] [#] [3] [0] [1] [#] [*]. Bosch Security Systems, Inc. Quick Reference Guide 2015.06 | 03 | F.01U.298.027...
  • Page 16: Set The Number Of Days Until The First Test Report

    Enter the Installer Code, followed by [6] and the [#] key. Two beeps sound. Zone LED for Zone LED for Report Event Receiver 1 Receiver 2 Telephone Line Seized Dialing Telephone Number / Network Connect 2015.06 | 03 | F.01U.298.027 Quick Reference Guide Bosch Security Systems, Inc.
  • Page 17: Walk Test Mode

    To exit Fault Analysis Mode and return to the disarmed state, press the [#] key. The FAULT indicator continues to display and the codepad stops sounding once a min. Bosch Security Systems, Inc. Quick Reference Guide 2015.06 | 03 | F.01U.298.027...
  • Page 18 (Horn Speaker, Siren Running, Strobe) is disconnected or short. This fault clears once all outputs are reconnected. Your installer must program the system for this feature to operate. 2015.06 | 03 | F.01U.298.027 Quick Reference Guide Bosch Security Systems, Inc.
  • Page 19 This fault occurs when any of the RF keyfobs report a low battery condition to the control panel. To determine which keyfob failed, press the [8] key. Only keyfob 1 to 16 faults display on the codepad through zone indicator 1 to 16. Bosch Security Systems, Inc. Quick Reference Guide 2015.06 | 03 | F.01U.298.027...
  • Page 20: Programming Parameters

    1 – 99 = 1 – 99 min. 4.1.2 Receiver 2 Item Location Option Default Phone Number 1 0040 - 0055 15 = Telephone termination Phone Number 2 0056 - 0071 15 = Telephone termination 2015.06 | 03 | F.01U.298.027 Quick Reference Guide Bosch Security Systems, Inc.
  • Page 21 For A-Link Plus, enter up to 32 case sensitive alphanumeric characters for CSVIP User Name and Password directly through keyboard. For text codepad, enter sensitive alphanumeric characters as below table. Bosch Security Systems, Inc. Quick Reference Guide 2015.06 | 03 | F.01U.298.027...
  • Page 22: External Network Module

    External Network Module Item Location Option Default External Network Module 0081 0 = Not used 1 = Use, do not configure 2 = Use and configure External Network Module 0082 2015.06 | 03 | F.01U.298.027 Quick Reference Guide Bosch Security Systems, Inc.
  • Page 23: Password For A-Link Plus/Rsc Connection

    0 = Panel does not answer 1 - 13 = No. of rings until panel answers 14 = Answering machine bypass 2 15 = Answering machine bypass 1 Bosch Security Systems, Inc. Quick Reference Guide 2015.06 | 03 | F.01U.298.027...
  • Page 24: Telephone Line Fail Options

    Location Option Default Communication Options 0179 1 = Set DTMF dialing pluses to 1 digit/sec 2 = Lockout telephone line fail alarm 4 = Reserved 8 = Reserved 2015.06 | 03 | F.01U.298.027 Quick Reference Guide Bosch Security Systems, Inc.
  • Page 25: A-Link Plus Options

    0240 - 0243 0244 User #13 0245 - 0248 0249 User #14 0250 - 0253 0254 User #15 0255 - 0258 0259 User #16 0260 - 0263 0264 Bosch Security Systems, Inc. Quick Reference Guide 2015.06 | 03 | F.01U.298.027...
  • Page 26 Master Code and Arm/Disarm and Arm/Disarm Reports Master Code and Arm/Disarm and Code Required to Isolate Master Code and Arm/Disarm and Code Required to Isolate and Arm/Disarm Reports Table 4.2: Authority Levels 2015.06 | 03 | F.01U.298.027 Quick Reference Guide Bosch Security Systems, Inc.
  • Page 27: Day Alarm Zones

    Zone Options 1 0291 Zone Options 2 0285 Zone Options 2 0292 Reserved 0286 Reserved 0293 Zone Report Options 0287 Zone Report Options 0294 Zone #05 Zone #06 Bosch Security Systems, Inc. Quick Reference Guide 2015.06 | 03 | F.01U.298.027...
  • Page 28 Zone Options 2 0341 Zone Options 2 0348 Reserved 0342 Reserved 0349 Zone Report Options 0343 Zone Report Options 0350 Zone #13 Zone #14 Zone Type 0351 Zone Type 0358 2015.06 | 03 | F.01U.298.027 Quick Reference Guide Bosch Security Systems, Inc.
  • Page 29 12 = 60 sec. 5 = 5 sec. 13 = 90 sec. 6 = 10 sec. 14 = 120 sec. 7 = 15 sec. 15 = 200 sec. Bosch Security Systems, Inc. Quick Reference Guide 2015.06 | 03 | F.01U.298.027...
  • Page 30: Swinger Programming

    Swinger Programming 4.7.1 Swinger Shutdown Count For Siren Item Location Option Default Swinger Shutdown Count 0379 1 – 15 = Number of times siren operates For Siren until lockout 2015.06 | 03 | F.01U.298.027 Quick Reference Guide Bosch Security Systems, Inc.
  • Page 31: Swinger Shutdown Count For Report

    5 = 24 hours (Only for Solution 2 = 2 hours 6 = 48 hours 3000 ) 3 = 4 hours 7 = 72 hours 4 = 12 hours Bosch Security Systems, Inc. Quick Reference Guide 2015.06 | 03 | F.01U.298.027...
  • Page 32: Radion Anti-Jamming Sensitivity

    Control Panel 4.9.2 RADION Anti-Jamming Sensitivity Item Location Option Default RADION Anti-Jamming Sensitivity 0394 0 = Most Sensitive (Only for Solution 3000 ) 15 = Least Sensitive 4.9.3 RF Receiver Item Location Option Default RF Receiver 0395 0 = Not used...
  • Page 33: System Status Programming

    1 = Report to Receiver 1 2 = Report to Receiver 2 4 = Report to both Receiver 1 and Receiver 2 8 = Report to Receiver 2 only if Receiver 1 fails Bosch Security Systems, Inc. Quick Reference Guide 2015.06 | 03 | F.01U.298.027...
  • Page 34: Output Programming

    Codepad Buzzer (Default = Entry/Exit Warning and Day Alarm) Event Code 0460 Event Code 0461 Polarity 0462 Time Base 0463 Time Base Multiplier 0464 Time Base Multiplier 0465 2015.06 | 03 | F.01U.298.027 Quick Reference Guide Bosch Security Systems, Inc.
  • Page 35 Event Code 0689 Polarity 0684 Polarity 0690 Time Base 0685 Time Base 0691 Time Base Multiplier 0686 Time Base Multiplier 0692 Time Base Multiplier 0687 Time Base Multiplier 0693 Bosch Security Systems, Inc. Quick Reference Guide 2015.06 | 03 | F.01U.298.027...
  • Page 36 Time Base 0739 Time Base Multiplier 0734 Time Base Multiplier 0740 Time Base Multiplier 0735 Time Base Multiplier 0741 For output item options, refer to below Output Item Options. 2015.06 | 03 | F.01U.298.027 Quick Reference Guide Bosch Security Systems, Inc.
  • Page 37 Mode 3 14 = Reserved 2 14 = Radio control output 2- not in AWAY 3 15 = Reserved Mode 2 15 = Communications fail after 3 attempts Bosch Security Systems, Inc. Quick Reference Guide 2015.06 | 03 | F.01U.298.027...
  • Page 38 When you program the output polarity as one shot, the time base is multiplied by the time base multiplier. (For example, if the time base = 2 and the multiplier = 05, the output operates for 5 sec.) 2015.06 | 03 | F.01U.298.027 Quick Reference Guide Bosch Security Systems, Inc.
  • Page 39: Time Programming

    0473 4.14.5 Delay Alarm Report Time Item Location Option Default Increments of 1 sec. (0 to 15 sec.) 0474 Increments of 16 sec. (0 to 240 sec.) 0475 Bosch Security Systems, Inc. Quick Reference Guide 2015.06 | 03 | F.01U.298.027...
  • Page 40: Sensor Watch Time

    Hour of the day (tens digit) 0482 Hour of the day (units digit) 0483 Minute of the day (tens digit) 0484 Minute of the day (units digit) 0485 2015.06 | 03 | F.01U.298.027 Quick Reference Guide Bosch Security Systems, Inc.
  • Page 41: Auto Disarming Time

    Location Option Default System Options 1 0492 1 = Bosch Security Systems smart lockout allowed 2 = Warning device fault monitor 4 = Strobe indication for radio arm/disarm 8 = Assign button 4 on keyfob to operate STAY Mode 1...
  • Page 42: System Options 3

    2 = Use digit 3 for codepad duress alarm (instead of digit 9) 4 = Alarms activate sirens and strobe outputs in STAY Modes 1 and 2 8 = Zone tamper alarms to be silent 2015.06 | 03 | F.01U.298.027 Quick Reference Guide Bosch Security Systems, Inc.
  • Page 43: Partitioning Options 1

    2 = Zone assigned to Area 2 1 = Zone assigned to Area 1 3 = Zone assigned to both Area 1 and Area 2 Notice! Solution 2000 supports zone 1 – 8 only. Bosch Security Systems, Inc. Quick Reference Guide 2015.06 | 03 | F.01U.298.027...
  • Page 44: Codepad Assignment

    3 = User code assigned to both Area 1 and Area 2 4.17 Default Options Item Location Option Default Button Default Options 0900 0 = Button Factory Default Enable 15 = Button Factory Default Disabled 2015.06 | 03 | F.01U.298.027 Quick Reference Guide Bosch Security Systems, Inc.
  • Page 45: Rfid Programming

    RF Zone #08 1890 - 1897 1898 RF Zone #09 1900 - 1907 1908 RF Zone #10 1910 - 1917 1918 RF Zone #11 1920 - 1927 1928 Bosch Security Systems, Inc. Quick Reference Guide 2015.06 | 03 | F.01U.298.027...
  • Page 46: Repeater Rfid

    0 = All Used 1 = Input 1 4 = Input 3 2 = Input 2 8 = Input 4 Table 4.5: RF Zone Options Notice! Only Solution 3000 supports zone/device RFID and repeater RFID. 4.18.3 Repeater RFID Item Location Default Item...
  • Page 47: User Names

    User 30 Name 3616 - 3639 User 15 Name 3256 - 3279 User 31 Name 3640 - 3663 User 16 Name 3280 - 3303 User 32 Name 3664 - 3687 Bosch Security Systems, Inc. Quick Reference Guide 2015.06 | 03 | F.01U.298.027...
  • Page 48: Appendices

    Single Zone input (Location 266 = 1k, 1k5, 2k2, 3k3, 3k9, 4k7, 5k6, 6k8, 10k, 12k, 22k) ZONE 1 Table 5.2: Connection 2 Double Zone with tamper (Location 266 = 14 (Split EOL3k3 / 6k8 with tamper 1k)) ZONE 5 (Solution 2000) ZONE 9 (Solution 3000) ZONE 1 (6K8 EOL) (3K3 EOL) Table 5.3: Connection 3...
  • Page 49: Wiring Diagram

    Siren AUX : < 900mA Slow flash: Normal state On: Trouble state Off: Trouble state Smoke detector Bosch SDI2 Bus 1,2,3 < 900mA 12V 7Ah 18VAC@1.33A Figure 5.1: Wiring Diagram Bosch Security Systems, Inc. Quick Reference Guide 2015.06 | 03 | F.01U.298.027...
  • Page 50: Component Overlay

    | Appendices Control Panel Component Overlay Figure 5.2: Component Overlay 2015.06 | 03 | F.01U.298.027 Quick Reference Guide Bosch Security Systems, Inc.
  • Page 51: Codepad Address Setting

    2 – Receiver interface connection 9 – Battery input 3 – Tamper switch 10 – Plug pack input (Bosch TF008) 4 – Zone 5-8 termination strip 11 - Bosch SDI2 Bus ( Zone 5 – 8 and Zone 13 – 16 for Solution 3000 ) 5 –...
  • Page 54 Bosch Security Systems, Inc. Bosch Sicherheitssysteme GmbH 130 Perinton Parkway Robert-Bosch-Ring 5 Fairport, NY 14450 85630 Grasbrunn Germany www.boschsecurity.com © Bosch Security Systems, Inc., 2015...