Table 88 Drive Interface Port Specification (Controller); Table 89 Mnt Port/Rmt Port/Fst Port Specifications; Table 90 Pwc Port Specifications - Fujitsu ETERNUS DX S5 Series Design Manual

Hybrid
Hide thumbs Also See for ETERNUS DX S5 Series:
Table of Contents

Advertisement

6. Hardware Configurations
Controller Enclosure
Drive Interface Ports
This port is used to connect drive enclosures.
The drive interface port specifications are shown below.
Table 88
Drive Interface Port Specification (Controller)
Interface
SAS
MNT Ports/RMT Ports/FST Ports
The MNT port is used for operation management and the FST port is used for maintenance. The RMT port is used
to separate the network from the MNT port for operation management.
FST ports are available for the ETERNUS DX500 S5/DX600 S5/DX900 S5.
The specifications for the MNT port, the RMT port, and the FST port are shown below.
Table 89
MNT Port/RMT Port/FST Port Specifications
Interface
Ethernet (1000BASE-T/100BASE-TX/10BASE-T)
PWC Ports
The PWC port is used to connect a power synchronized unit to perform power synchronization.
The PWC port specifications are shown below.
Table 90
PWC Port Specifications
Interface
RS232C
Transfer rate (max.)
Connector type
12Gbit/s
miniSAS HD
(SFF-8644)
Transfer rate
(max.)
1Gbit/s
Connector type
PWC
263
Number of ports for each controller
1 (ETERNUS DX60 S5/DX100 S5/DX200 S5)
4 (ETERNUS DX500 S5/DX600 S5/DX900 S5)
Connector type
Number of ports for each controller
RJ-45
1 (MNT)
1 (RMT)
1 (FST)
Number of ports for each controller
1
Design Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents