Table 127 Combinations Of Functions That Can Be Executed Simultaneously (2/2) - Fujitsu ETERNUS DX S5 Series Design Manual

Hybrid
Hide thumbs Also See for ETERNUS DX S5 Series:
Table of Contents

Advertisement

B. Function Specification List
Combinations of Functions That Are Available for Simultaneous Executions
Table 127
Combinations of Functions That Can Be Executed Simultaneously (2/2)
Process to be run
Volume
formatting
RAID Migration
Logical Device
Expansion
LUN
Concatenation
Advanced Copy
(*2)
Volume
Conversion
Encryption
Switching the
controlling CM
TPV capacity
expansion
TPV Balancing
TPV/FTV capacity
optimization
FTRP Balancing
¡: Possible, ´: Not possible
*1 : This indicates that the copy session is being set or the copy session is already set.
*2 : This indicates the copy session setting operation.
*3 : Volume formatting will cause losing the entire data in volumes.
*4 : The function cannot be executed when the same volume is set as the execution target.
*5 : LUN concatenated volumes can be set as the RAID Migration source.
Note that LUN concatenated volumes cannot be set as the RAID Migration destination.
*6 : RAID Migration that expands the capacity cannot be performed on any volumes with copy sessions in LUN units.
*7 : The function cannot be executed when the same RAID group is set as the execution target.
*8 : When a copy session with a copy area that is specified in LUN units exists, volume capacity expansion cannot be performed because
copying cannot be processed for the expanded part. When a copy session is specified for a logical disk, volume capacity expansion can
be performed.
*9 : Copy sessions in LUN units cannot be performed on a volume that is being expanded with RAID Migration.
*10: Complies with Advanced Copy specifications (multi-copy/Cascade Copy).
*11: The REC session needs to be suspended or stopped before the operation.
*12: The motor-off state of Eco-mode is stopped, and the drive motor is activated (spin-up).
*13: EC/REC can be performed (the motor-off state of Eco-mode will be stopped).
OPC/QuickOPC/SnapOPC/SnapOPC+ cannot be performed (the ETERNUS DX returns an error).
Already running process
Volume
Eco-mode
Disk Drive
Conversion
(motor is
Patrol
Encryption
stopped)
¡ (*3)
¡
¡ (*12)
¡ (*4)
¡
¡ (*12)
¡ (*7)
¡
¡ (*12)
¡ (*4)
¡
¡ (*12)
¡
¡
¡ (*13)
¡ (*4)
¡ (*12)
¡
¡ (*7)
¡
¡
¡
¡
¡ (*12)
¡
¡
¡ (*12)
¡
¡
¡ (*12)
¡
¡
¡ (*12)
TPV/FTV
TPV
capacity
Balancing
optimization
¡ (*4)
¡
¡ (*4)
¡ (*4)
¡
¡
¡
¡
¡
¡
¡
¡
¡
¡
¡ (*4)
¡
¡ (*4)
¡ (*4)
´
¡ (*4)
¡ (*4)
¡ (*4)
326
Storage
Cluster
¡ (*4)
¡
¡
¡ (*4)
¡
¡
¡
¡
¡
¡
¡
Design Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents