5. Connection Configuration
LAN Connection
Note
• Each CM has an LED that lights up green to identify when it is the Master CM.
• Setting the IP address of the Slave CM ensures that ETERNUS Web GUI or ETERNUS CLI can be used from
the Slave CM if an error occurs on the LAN path for the Master CM.
The Master CM and the Slave CM perform different functions. The Slave CM can only switch the Master
CM and display the status of the ETERNUS DX.
The IP address of the Slave CM does not need to be set for normal operation.
Figure 105
ETERNUS DX
LAN Control (When the IP Address of the Slave CM Is Set)
LAN path
error
Master CM
IP address A
CM#0
Controller enclosure
Slave CM
IP address B
CM#1
The IP address of the Slave CM is
used to switch the Master CM and
display the status of the ETERNUS DX.