Shortest Repetition Period For Triggers; Shortest Trigger Pulse Width; When [Exposure Mode] Is [Off] - IAI WA-1000D-CL User Manual

Swir ingaas line scan camera
Table of Contents

Advertisement

Shortest Repetition Period for Triggers

Trigger Mode ON, full resolution
Exposure Mode OFF
Exposure Mode Timed
PWC

Shortest Trigger Pulse Width

Trigger Mode ON
Exposure Mode OFF
Exposure Mode Timed
PWC

■ When [Exposure Mode] is [Off]

Perform accumulation and scanning using triggers from an external source.
As the accumulation control is performed using the camera's internal counter, accumulation will not be
affected by trigger jitter.
• Actual exposure time: trigger period
• Shortest trigger period: 25.48 μs (20.38 μs exposure time)
*1 Recommended input range for trigger period: 25.48 μs to 2.0 ms
™ The electronic shutter cannot be used in this mode.
™ In this mode, only gain control will operate for One Push channel balance.
Caution
Be aware that the jitter that occurs in input triggers will result in accumulation errors.
TRIGGER
Exposure Active
(Sensor Video 1/8 tap)
LVAL
DATA
Camera Link
12-pin
Camera Link
12-pin
Camera Link
12-pin
Camera Link
20.48 μs
20.48 μs
20.48 μs
- 5.1 μs
*1
25.79 us (min)
1.37 us ± 0.075 us
20.38 us to 1995 us
̶ 25 ̶
Shortest period (μs)
Exposure time + (25.48 - 20.38)
12-pin
50 μs
50 μs
50 μs
1.37 us ± 0.075 us
5.1 us (min)
6 spclk
0.94 us ± 0.075 us
128 spclk
19.189 us
25.3 us
1024 pclk
19.189 us
WA-1000D-CL

Advertisement

Table of Contents
loading