Image processing
Operation mode
Trigger inputs
Synchronous output (when
the terminal is open)
Communication interface
Field update
Power supply voltage
Lens mount
Flange back
Optical axis accuracy
Bonding accuracy
Operating temperature /
humidity
Storage temperature /
humidity
Vibration resistance
Impact resistance
Standard compliance
*2
Dimensions
Weight
1 Pixel sensitivity correction: Pixel correction (DSNU, PRNU)
2 Defective pixel correction: Up to 16 pix
3 Shading correction: ON/OFF switchable
SWIR ch1: Flat Field correction possible.
SWIR ch2: Flat Field correction, correction matching SWIR ch1 selectable.
4 LUT/Gamma function: 1.00 (OFF) / 0.45 / User (LUT) selectable
When set to User, table data can be applied from externally.
Table data can be configured individually.
5 Lens aberration correction ±3 pix
6 Noise reduction: Individual ON/OFF switching possible for Sensor 1 and
Sensor2.
• Exposure Mode OFF mode (Internal/External trigger)
• Shutter select mode (Internal/External trigger)
• PWC (External trigger)
12-pin: 3.5 ± 1.5 V (p-p) TTL input
Camera Link: LVDS (CC1)
Positive / negative logic switchable.
Minimum trigger width: EPS 500 ns or more / PWC 61.8 μs or more
™ Use either 12-pin or Camera Link for trigger inputs.
Camera Link
• LVAL (Camera Link Tx24)
• DVAL (Camera Link Tx25)
• EEN (Camera Link Tx26)
12-pin
• XEEN (negative logic) 4.0 Vp-p (when there is no
termination)
EIA-644: Camera Link CC1
RS-232C: 12-pin
Communication rate: 9600 bps
™ Switchable via the rear panel DIP switch.
™ EIA-644 and RS-232C cannot be used simultaneously.
Supported
DC input range: +12 V to 24 V ±10%
820 mA ±10% (current consumption at DC +12 V supply)
Conditions: For 12 V input (Internal Trigger / Line Rate = 600 μs / Gain 0 dB /
light shield / ambient temperature 25°C)
™ Use a power supply that can provide 3 A or more.
WA-1000D-CL-M52: M52-mount standard
™ Lens mount protrusion length of 13 mm or less is supported.
M52-mount: 46.5 mm (in air), tolerance: ±0.1 mm
Center ±0.1 mm (Max)
Within ±0.5 pixels (center)
™ Above accuracy based on factory testing.
-5°C to +45°C / 20% to 80% (non-condensing)
-25°C to +60°C / 20% to 80% (non-condensing)
3G (20 Hz to 200 Hz XYZ directions)
50G
CE (EN61000-6-2, EN61000-6-3)
RoHS/WEEE
IEC/EN61000-4-3
FCC Part15 Class B
IEC61000-4-2 Level 4 (contact discharge = 8 kV, air discharge = 15 kV)
90 × 90 × 117 mm (WHD) (excluding mount and protrusions)
910 g
̶ 43 ̶
WA-1000D-CL