IAI WA-1000D-CL User Manual page 28

Swir ingaas line scan camera
Table of Contents

Advertisement

Exposure Active
(Sensor Video 1/8 tap)
LVAL
DATA
Spclk (Sensor Pixel clock): 149.92 ns (6.67 MHz)
pclk (Cameralink Pixel clock): 18.74 ns (53.36 MHz: SPCLK × 8)
When [Exposure Mode] is [Timed]
Perform accumulation and scanning using triggers generated internally on the camera.
As the accumulation control is performed using the camera's internal counter, accumulation will not be
affected by trigger jitter.
In addition, accumulation control can be performed individually for ch1 and ch2.
Line period
• Variable range: 25.48 μs (1L) to 2.0 ms
• Variable unit: 149.9 ns (1clk)
Electronic shutter
• Variable range: 20.38 μs (1L) to 1.995 ms
• Variable unit: 149.9 ns (1clk) (individual ch1/ch2 control possible)
*1 The maximum duration will be the configured line period minus 5.1 μs.
Exposure Active
(Sensor Video 1/8 tap)
LVAL
DATA
Spclk (Sensor Pixel clock): 149.92 ns (6.67 MHz)
pclk (Cameralink Pixel clock): 18.74 ns (53.36 MHz: SPCLK × 8)
20.38 us to 1995 us
(individual ch1/ch2 control possible)
*1
20.38 us to 1995 us
̶ 28 ̶
5.1 us (min)
6 spclk
0.94 us ± 0.075 us
128 spclk
19.189 us
25.3 us
1024 pclk
19.189 us
5.1 us to 1979.62 us
6 spclk
0.94 us ± 0.075 us
128 spclk
19.189 us
25.3 us
1024 pclk
19.189 us
WA-1000D-CL

Advertisement

Table of Contents
loading