Set [Exposure Mode] to [Trigger Width] .
When you select [Trigger Width], [Trigger Mode] will automatically be set to [On].
2
Set [Trigger Selector] to [Line Start].
([Line Start] is the default setting.)
3
If necessary, change the [Trigger Source] and [Trigger Activation] settings.
When [Exposure Mode] is set to [Off] or [Timed], [Trsigger Mode] can be set to [Off].
[Exposure Mode] can be set to [PWC] only when [Trigger Mode] is set to [On].

Control Without External Triggers

When Controlling the Exposure Time Using Specified Exposure Times

Configure the settings as follows.
Item
Trigger Selector (trigger
operation)
Trigger Mode
Exposure Mode
Exposure Time
1
Set [Exposure Mode] to [Timed].
([Timed] is the default setting.)
2
Specify the exposure time in [Exposure Time].
The setting value for the exposure time can only be changed when [Exposure Auto] is set to [Off].
If [Exposure Auto] is set to [Continuous], temporarily set it to [Off] before changing the [Exposure
Time].
3
Set [Trigger Mode] to [On].

When Not Controlling the Exposure Time

Configure the settings as follows.
Item
Exposure Mode
The exposure will be performed with an exposure time equal to 1 / frame rate.
* [Exposure Time] is disabled.
Setting value / selectable range
Line Start
Off
Timed (control via exposure time)
Dependent on the [Exposure Mode] and [Acquisition Line Rate] settings.
Setting value / selectable range
Off