Compressed Air Supply, Control Air; Ambient Conditions - MBO RW500 Operating Manual

Rewinder
Table of Contents

Advertisement

Product description
Technical data
3.2.7

Compressed air supply, control air

Compressed air supply
Connected loads
Connecting line
Table 18: Compressed air supply, control air
1) Required volume flow according to ISO 1217 or DIN 1945
2) Purity class according to ISO 8573-1:2010 [particles:water:oil].
3) Typical purity classes for the publishing and print sector (control air) in compliance with VDMA standard sheet
15390-1:2014-12, table 5.
3.2.8

Ambient conditions

Room temperature
Storage temperature
Relative humidity
2)
Set-up height
Table 19: Ambient conditions
1) At temperatures below or above the permissible room temperature, special measures must be taken.
2) For installation at an altitude of 1000 m above sea level or higher, a power reduction of 1 % per 100 m should
be incorporated.
46
Necessary network pres-
sure
Average consumption
2)
Purity class
Schott plug connection
Hose with external diame-
ter
Optimal
Minimum
Maximum
Avoid direct sunlight and drafts.
Minimum
6 bar
1)
10 l/min
ISO 8573-1:2010 [3:4:2]
QSS-8
8 mm
1)
17 ... 35 °C
10 ... 35 °C
40 - 60 %
30 %
80 % (non-condensing)
Max. 1500 above sea level
Maximum
7 bar
3)