Maintenance
Performing operational maintenance
9.4.1.2
Check interlocking movable guard with guard locking
Prerequisites
Checking the
interlocking
movable guard
130
For safety reasons, the function of the interlocking movable guard must be
checked every day.
Proceed as follows to test the interlocking movable guard with guard lock-
ing.
These prerequisites must be fulfilled:
• The <Production> operating mode is switched on.
The <Setup/production operating mode> illuminated push button is lit in
green.
1 Interlocking movable guards with guard locking
Illustration 67: Interlocking movable guard with guard locking
Here's how to check the interlocking movable guard:
1)
Try opening the movable guard.
The movable guard is not permitted to be opened due to the guard
locking.
2)
Press the <Setup/production> illuminated button for approx. 3 sec-
onds to switch to the <Setup> operating mode.
The illuminated button is lit yellow.
3)
Try opening the movable guard.
The interlocking movable guard should now open.
4)
Close the interlocking movable guard.
5)
Press the <Setup/production> illuminated button for approx. 3 sec-
onds to switch to <Production> operating mode.
The illuminated button is flashing green.
The interlocking movable guard is checked.
The interlocking moveable guards are not permitted to be openable in
the <Production> operating mode.