Configuration Menu Function (Config) - ITech IT8300 Series User Manual

Regenerative dc electronic load
Hide thumbs Also See for IT8300 Series:
Table of Contents

Advertisement

PROTOCOL
SCPI(Def)
Protocol
Extend-Table
PARALLEL SETUP
Single
Parallel
Slave
Master
Restored to Factory Setting (>Reset)
This option is used to restore all settings in the system menu to factory setting
values. Select "YES" and Press [Enter] to restore to factory setting values. In
this case, all set values in the system will be restored to factory setting values,
i.e., the (Def) mark values.
Power on (>Power-on)
This parameter determines the state of electronic load after power up. If you
select "Rst", the default input parameter settings will be active after power up.
The default setup is 0V and 0A. If you select "Sav0", then the electronic load will
automatically recall the input parameters setting saved in 0 register.
Key Sound Set (>Buzzer)
This item can set the key sound state. If in On mode, the electronic load will
issue beeper sound when you press any button. If in Off mode, the beeper will
not make a sound. The default set is in On mode.

3.7 Configuration menu function (Config)

Press [Shift] + 9(Config) to enter menu configuration (CONFIG MENU).
Living
Von
Latch
P-Limit
Protect
I-Protect
20K: Baud rate
Addr: Address of load
Prescaler: Prescaler
BS1 Value: Not settable
BS2 Value: Not settable
SCPI protocol.
Expand SCPI protocol for compatibility of other
machines.
Single mode
Act as a slave mode
Act as a master mode
Total = 3
Set total number of instruments in parallel.
Point= 2V
Hysteresis=0.5V
Point= 2V
Point=150W
On
Point=30A
Copyright © ITECH Electronics Co., Ltd.
Communication protocol selection
Parallel mode set up
Von point living state, ON /OFF
Set the Von value
Indicates the hysteresis voltage,
when the voltage falls below that
value, the Von function is
maintained.
Von point latch state, ON /OFF
Set the Von value
Set hardware protective power
value.
Set the maximum power.
Set software current protection.
Start function.
Set software current protective
value.
Function and Features
13