DT1 enabled.

4.3 LAN Interface

Connect the LAN interface of load to the computer with a reticle (crossed).
1.
Press [Shift] + 8(System) button to enter the system set.
2.
Press the Right key to select Communication and press [Enter] for setting.
3.
Press the Right key to select LAN and press [Enter] for setting.
4.
Set the Gateway, IP, Mask and Socket Port in the LAN option.
The gateway address should be consistent with that of the PC, and the IP
address should be at the same network segment with the PC's IP address.

4.4 CAN Interface

There is one CAN interface at the rear panel. The user can use this terminal for
PC connection; to activate connection, be sure that the values set in the
System menu are same as the corresponding values set in PC.
CAN setting in the program shall be consistent with the one set in the System menu of front
panel. To query and change, press the composite key [Shift] + 8(System) to enter the
setting screen in System menu for query and change. For details, refer to 3.6 System Menu.
Baud Rate
In the front panel [Shift] + 8(System), under the System menu, the user can
select one Baud rate stored in NVM:
20K|40K|50k|80k|100k|125k|150K|200k|250k|400K|500K|1000K
CAN Pin Definition
CAN interface pin is as follows.
CAN Troubleshooting:
If CAN connection fails, check that:
1.
The PC and load have same Baud rate.
2.
Appropriate interface pin or adapter is used, as described in CAN
connector.
3.
The interface cable is correctly connected (CAN_H to CAN_H, CAN_L to
CAN_L).
Check whether 120 Ω terminal resistance is connected.
4.
Note
CAN interface pin
Copyright © ITECH Electronics Co., Ltd.
References of Load Communication Interfaces
Pin
Description
H
CAN_H
L
CAN_L
39

Advertisement