Rotate adjusting knob to set constant resistance value.
Use numeric keys to input resistance value and press [Enter] key to
confirm set constant resistance value.
Use
corresponding positions.
Operation steps
1.
Press [CR] key and [Shift] + [CV] to enter parameter setting screen.
Constant
Range=1200.000Ω
2.
Set maximum working resistance value and press [Enter] for confirmation.
Constant
Range=1000.000Ω
3.
Set maximum voltage value and press [Enter] key.
Constant
High=80.00V
4.
Set minimum voltage value and press [Enter] key.
Constant
Low=0.00V
5.
Complete parameter setting.
10.00V
0W
3.2.4 Constant power operation mode (CW)
Under CW mode, the electronic load will consume a constant power, as shown
below. If input voltage rises, the input current decreases and power P (= V * I)
will maintain at setting power. As shown in Fig. 3-4.
Input
voltage
Under CW mode, the electronic load provides three ways to modify constant
power.
Rotate adjusting knob to set constant power value.
moving cursor and press
Resistance
Resistance
Resistance
Resistance
0.0A
CR=2.000Ω
Note
If the above method is for editing auto test step (as mentioned below), constant
resistance range can also be set.
V
Set power
V2
V3
I2
I3
Load current
CW mode
Fig. 3-4 Voltage-Current Relation Schema under CW Mode
Copyright © ITECH Electronics Co., Ltd.