3. The software prompts you to input the Reset Polarity or to set the
Note: You only need to answer these questions once during
programming, regardless of the quantity selected. If you configure
the programmer by opening a profile, you are not prompted to
answer these questions since these settings are part of the profile.
4. If the specified device quantity is more than 1, the message
HW-130 Programmer User Guide
Device Secured field depending on the device selected. Not all
options are available for all devices.
Select High or Low active Reset. High is the default.
Select the desired security.
Depending on the device selected, several security; options
may be available:
1. Select No to disable the security feature (the default).
2. Select Yes to activate the security feature.
3. Select Secure Only to secure a previously programmed
device.
Note: For some other devices several other security
alternatives can also be selected:
Read Secure -- This option disables the device from being
read, but still permits it to be erased and reprogrammed.
Write Secure -- This option allows the device to be read, but
disables the ability to erase and reprogram.
Read and Write Secure -- This invokes both types of security
as listed above.
Once secured, only the signature string can be read.
"Please Insert Device N of M in the Socket" is
displayed, where N is the current device and M is the maximum
quantity selected. Place the first device you wish to program in
the socket adapter. To program the next devices, you can also
initiate the program command by pressing the programmer push-
button.
Check the status bar to view the progress of the programming
operation. After programming the device, the software updates
the Pass/Fail and Device Checksum fields on the display.