Error Message and Handling
Serious Error
This section describes the contents of reboot-required errors as well as the check items and recovery
actions.
Error
VC2E-MM-00
Event/Symptom
Media detection failed
Media detection failed
Media detection failed
Abnormal condition in PF motor
(X-axis)
60
MAINTENANCE MANUAL
Troubleshooting
Are Pinch Rollers installed correctly?
Check the width sensor in self-diagnosis.
<Parts may be broken>
AASII carriage board Assy
Watch dog-Interface converter board Assy
Main board Assy
Flat cable Assy
Are Pinch Rollers installed correctly?
Check the width sensor in self-diagnosis.
<Parts may be broken>
AASII carriage board Assy
Watch dog-Interface converter board Assy
Main board Assy
Flat cable Assy
Are Pinch Rollers installed correctly?
Check the width sensor in self-diagnosis.
<Parts may be broken>
AASII carriage board Assy
Watch dog-Interface converter board Assy
Main board Assy
Flat cable Assy
Remove the obstacle that prevents the X-axis
operation.
Check if a media is jammed on the machine.
Check "X Encoder" and "Drum Movement" in
self-diagnosis.
<Parts may be broken>
X-motor
Main board Assy