Diagnostic Test for Motor Encoder and Tool Holder Encoder

It diagnoses the X and Y motor encoder and tool holder encoder. If the encoder is defective, the cutting
plotter cannot work properly. To check if the encoder is bad or good, you can apply a slight force to the
tested part (such as a drum, tool carriage or tool holder) then examine the readings. If the encoder
reading changes dramatically or does not change at all, the encoder is bad. To replace the motor or tool
carriage, please refer to the maintenance chapter.
X Motor Encoder Test

Y Motor Encoder Test

VC2E-MM-00
ON/OFF LINE key
ON/OFF LINE key
ENTER key
3 seconds later
ENTER key
3 seconds later