Acceleration, Deceleration, And Rotation Limits - Omron LD-250 User Manual

Platform
Hide thumbs Also See for LD-250:
Table of Contents

Advertisement

4.3  Acceleration, Deceleration, and Rotation Limits

4.3 Acceleration, Deceleration, and Rotation Limits

For safety, an AMR has default limits on its maximum linear and rotational acceleration, decel-
eration, and speed. You can change the parameters that control these limits. However, chan-
ging the limits might affect the AMR's stability, depending on the center of gravity (CG) of the
combined LD-250 and its payload.
!
If your payload's center of gravity is not within the guidelines provided in Center of Gravity
(CG) on page 86, you might need to adjust the Absolute Movement Maximums parameter val-
ues in the MobilePlanner software.
For payload applications where you cannot easily reduce the size and weight of the payload or
if the AMR's CG is not within the recommended limits, contact your local Omron Support.
Table 4-1 lists the Absolute Movement Maximums parameter limits and defaults. The first
four parameters have the least significant impact on the AMR's stability. All *Accel and *Decel
parameters have a significant impact. If the payload is asymmetric, you might need to adjust
the value of AbsoluteMaxRotVel.
AbsoluteMaxTransVel
AbsoluteMaxTransNegVel
AbsoluteMaxTransAccel
AbsoluteMaxTransDecel
AbsoluteMaxRotVel
AbsoluteMaxRotAccel
AbsoluteMaxRotDecel
a: The LD-250's safety system generates a fault if the velocity is in the range -300 mm/s to -2500
mm/s.
After you determine your parameter values, set them as follows:
1. Open the MobilePlanner software, Config tab.
2. Navigate to:
Robot Physical > Absolute Movement Maximums
3. Check the box for Show Expert + Parameters (top right of screen) to see or modify these
parameters.
4. Adjust the parameter values according to Table 4-1.
74
CAUTION: PROPERTY DAMAGE RISK
If you change the value of the AbsoluteMaxTransVel parameter, re-commission
the AMR before putting it into service.
Table 4-1 Absolute Movement Maximums Parameters
Parameter
Default
1200
-200
600
2000
120
360
360
LD-250 Platform User's Guide
Min
Max
Your Min Your Max
1
32767
a
-32767
32767
1
32767
1000
32767
1
32767
1
32767
a
-32767
32767
20472-000 Rev B