I.6 Troubleshooting - YASKAWA Z1000U Series Quick Start Manual

Low harmonic hvac matrix drive for hvac applications
Hide thumbs Also See for Z1000U Series:
Table of Contents

Advertisement

HOA Keypad Display
oPE27
oPE28
oPE30
u
Auto-Tuning Errors
n
Auto-Tuning Codes
Auto-Tuning faults in this section are displayed on the HOA keypad and will cause the motor to coast to a stop. Auto-Tuning
faults do not trigger a multi-function digital output set for fault or alarm output.
An Endo error on the HOA keypad display indicates Auto-Tuning has successfully completed with discrepancies in the
calculations. Restart Auto-Tuning after fixing the cause of the Endo error.
The drive may be used in the application if no cause can be identified despite the existence of an Endo error.
An Ero error indicates that Auto-Tuning has not completed successfully. Check for the cause of the error using the tables in
this section, and perform Auto-Tuning again after fixing the cause.
HOA Keypad Display
End3
End4
End5
End7
Er-01
Er-02
Er-03
Er-04
Er-05
Er-08
Er-09
Er-12
u
Fault Reset Methods
When a fault occurs, the cause of the fault must be removed and the drive must be restarted. The table below lists the different
ways to restart the drive.
After the Fault Occurs
Fix the cause of the fault, restart the drive, and
reset the fault.
Resetting via Fault Reset Digital Input S4
Turn off the main power supply if the above methods do not reset the fault. Reapply power after the
HOA keypad display has turned off.
When an "SC" error occurs, contact Yaskawa or a Yaskawa agent before cycling the power to the drive.
Note:
If the Run command is present, the drive will disregard any attempts to reset the fault. Remove the Run command before attempting to clear
a fault situation.
YASKAWA ELECTRIC TOEP C710636 11E Z1000U HVAC MATRIX Drive Quick Start Guide
BP Program Error
Bypass mode is not correctly configured.
Sequence Timer Error
One or more of the sequence timers is not set in the correct order.
Incorrect Input Voltage Adjustment
The input voltage offset adjustment has not been performed.
Rated Current Setting Alarm (displayed after Auto-Tuning is complete)
Adjusted Slip Calculation Error
Resistance Tuning Error
No-Load Current Alarm
Motor Data Error
Minor Fault
STOP Button Input
Line-to-Line Resistance Error
No-Load Current Error
Rated Slip Error
Acceleration Error
Current Detection Error
Press
on the HOA keypad when the error code
is displayed.
Close then open the fault signal digital input via
terminal S4. S4 is set for "Fault Reset" as default
(H1-04 = 14).
Error Name
Error Name
Procedure
Fault Reset Switch

i.6 Troubleshooting

ALM
DIGITAL OPERATOR JVOP-183
-DRIVE-
-Rdy-
Freq Ref (OPR)
U1- 01=60.00Hz
----------------
U1- 02=60.00Hz
JOG FWD FWD/REV
F1
F2
M
M
ESC
HAND
RESET
ENTER
AUTO
OFF
Drive
S4 Fault Reset Digital Input
SN Digital Input Common
SC
SP
ON
2
OFF
1
69