YASKAWA Z1000U Series Quick Start Manual page 75

Low harmonic hvac matrix drive for hvac applications
Hide thumbs Also See for Z1000U Series:
Table of Contents

Advertisement

No.
Name
Maximum Output
E1-04
Frequency
E1-05 Maximum Voltage
E1-06 Base Frequency
E1-07 Middle Output
Frequency
E1-08 Middle Output
Frequency Voltage
Minimum Output
E1-09
Frequency
Minimum Output
E1-10
Frequency Voltage
Middle Output
E1-11
Frequency 2
Middle Output
E1-12
Frequency Voltage 2
E1-13 Base Voltage
E2-01 Motor Rated Current
E2-11 Motor Rated Power
E5-01 Motor Code Selection
(for PM Motors)
E5-02 Motor Rated Power
E5-03 Motor Rated Current
E5-04 Number of Motor Poles Sets the number of motor poles.
E5-05 Motor Stator Resistance Set the resistance for each motor phase.
E5-06 Motor d-Axis
Inductance
E5-07 Motor q-Axis
Inductance
E5-09 Motor Induction
Voltage Constant 1
Motor Induction
E5-24
Voltage Constant 2
Communications Error
F6-01
Operation Selection
H1-01
Multi-Function Digital
to
Input Terminal S1 to S8
H1-08
Function Selection
H2-01
Multi-Function Digital
to
Output Terminal
H2-03
Function Selection
H2-06 Power Consumption
Output Unit Selection
H2-07 MEMOBUS Register 1
Address Select
YASKAWA ELECTRIC TOEP C710636 11E Z1000U HVAC MATRIX Drive Quick Start Guide
Description
These parameters are only applicable when
E1-03 is set to F.
To set linear V/f characteristics, set the
same values for E1-07 and E1-09.
In this case, the setting for E1-08 will be
disregarded. Ensure that the four
frequencies are set according to these rules:
E1-09 ≤ E1-07 < E1-06 ≤ E1-11 ≤ E1-04
Output Voltage (V)
E1-05
E1-12
E1-13
E1-08
E1-10
E1-09
E1-07 E1-06 E1-11 E1-04
Frequency (Hz)
Sets the motor nameplate full load current
in amps. Automatically set during
Auto-Tuning.
Sets the motor rated power in kilowatts
(1 HP = 0.746 kW). Automatically set
during Auto-Tuning.
Enter the Yaskawa motor code for the PM
motor being used. Various motor
parameters are automatically set based on
the value of this parameter. Settings that
were changed manually will be overwritten
by the defaults of the selected motor code.
Sets the rated capacity of the motor.
Sets the motor rated current.
Sets the d-Axis inductance for the PM
motor.
Sets the q-Axis inductance for the PM
motor.
Sets the induced peak voltage per phase in
units of 0.1 mV/(rad/s) [electrical angle].
Sets the induced phase-to-phase rms
voltage in units of 0.1 mV/(r/min)
[mechanical angle].
0: Ramp to stop. Decelerate to stop using
the deceleration time in C1-02.
1: Coast to stop
2: Fast Stop. Decelerate to stop using the
deceleration time in C1-09.
3: Alarm only
Selects the function of terminals S1 to S8.
Selects the function of terminals M1-M2,
M3-M4, and MD-ME-MF.
0: 0.1 kWh units
1: 1 kWh units
2: 10 kWh units
3: 100 kWh units
4: 1000 kWh units
Note: The setting range is 1 to 4 in drive
software versions PRG: 6113 and earlier.
Sets the addresses of the MEMOBUS/
Modbus registers from which data will be
sent to contact outputs 62 and 162.
No.
Name
H2-08 MEMOBUS Register 1
Bit Select
MEMOBUS Register 2
H2-09
Address Select
MEMOBUS Register 2
H2-10
Bit Select
Terminal A1 Signal
H3-01
Level Selection
Terminal A1 Function
H3-02
Selection
Terminal A1 Gain
H3-03
Setting
Terminal A1 Bias
H3-04
Setting
Terminal A3 Signal
H3-05
Level Selection
Terminal A3 Function
H3-06
Selection
H3-07 Terminal A3 Gain
Setting
H3-08 Terminal A3 Bias
Setting
H3-09 Terminal A2 Signal
Level Selection
H3-10 Terminal A2 Function
Selection
Terminal A2 Gain
H3-11
Setting
Terminal A2 Bias
H3-12
Setting
Analog Input Filter
H3-13
Time Constant
H3-14 Analog Input Terminal
Enable Selection
H3-16 Terminal A1 Offset
H3-17 Terminal A2 Offset
H3-18 Terminal A3 Offset
Multi-Function Analog
H4-01
Output Terminal FM
Monitor Selection
Multi-Function Analog
H4-02
Output Terminal FM
Gain
i.8 Parameter Table
Description
Sets the bits for the MEMOBUS/Modbus
registers from which data will be sent to
contact outputs 62 and 162.
Sets the addresses of the MEMOBUS/
Modbus registers from which data will be
sent to contact outputs 63 and 163.
Sets the bits for the MEMOBUS/Modbus
registers from which data will be sent to
contact outputs 63 and 163.
0: 0 to 10 V with zero limit
1: 0 to 10 V without zero limit
2: 4-20 mA
3: 0-20 mA
Note: Use Jumper S1 to set input terminal
A1 for a current or voltage input signal.
Sets the function of terminal A1.
Sets the level of the input value selected in
H3-02 when 10 V is input at terminal A1.
Sets the level of the input value selected in
H3-02 when 0 V is input at terminal A1.
0: 0 to 10 Vdc (20 kΩ)
1: 4 to 20 mA (250 Ω)
2: 0 to 20 mA (250 Ω)
Sets the function of terminal A3.
Sets the level of the input value selected in
H3-06 when 10 V is input at terminal A3.
Sets the level of the input value selected in
H3-06 when 0 V is input at terminal A3.
0: 0 to 10 V with zero limit
1: 0 to 10 V without zero limit
2: 4 to 20 mA
3: 0 to 20 mA
Note: Use Jumper S1 to set input terminal
A2 for a current or voltage input signal.
Sets the function of terminal A2.
Sets the level of the input value selected in
H3-10 when 10 V (20 mA) is input at
terminal A2.
Sets the level of the input value selected in
H3-10 when 0 V (0 or 4 mA) is input at
terminal A2.
Sets a primary delay filter time constant for
terminals A1, A2, and A3. Used for noise
filtering.
1: Terminal A1 only
2: Terminal A2 only
3: Terminals A1 and A2 only
4: Terminal A3 only
5: Terminals A1 and A3
6: Terminals A2 and A3
7: All terminals enabled
Adds an offset when the analog signal to
terminal A1 is at 0 V.
Adds an offset when the analog signal to
terminal A2 is at 0 V.
Adds an offset when the analog signal to
terminal A3 is at 0 V.
Selects the data to be output through multi-
function analog output terminal FM.
Set the desired monitor parameter to the
digits available in Uo-oo.
For example, enter "103" for U1-03.
Sets the signal level at terminal FM that is
equal to 100% of the selected monitor
value.
75