battery characteristic simulation in the "Current Shut(A)" column.
8.
Press the [Start] soft key to start battery simulation test.
9.
The CH2 of the power supply will automatically switch off the output, once
the battery according to the characteristic data completes the test or the
setting conditions for stopping the test is reached. You can press [Stop] to
pause the test during the battery simulation test. And press [Capacity
Clear] to restart the test.