Taking the OVP as example, detailed configuration steps are as follows:
1.
2.
3.
4.
5.
6.
7.
Over Voltage Protection(OVP)
Press the [Menu] key to enter the Power Menu Configuration interface.
Select "Config > Conf1" to enter the Configuration Menu interface.
Press the [Channel(1/2)] soft key to select editing CH1.
Press the Up/Down key to move the cursor to the configuration position of
OVP functional state, as shown in the figure below:
Press the corresponding soft key at right to configure the OVP functional
state. On: Switch on the OVP function; Off: Switch off the OVP function.
Press the Up/Down key to move the cursor to the configuration position of
OVP function protection point and directly use the Numeric keys or
Left/Right key and knob for adjustment to configure the voltage protection
point value.
If the OVP protection function is on, the
display screen.
Software over-voltage protection: when the over-voltage protection is
enabled, the voltage at the power output terminal is limited to the value set
by the over voltage protection. If the over-voltage protection is triggered,
the output will immediately be switched off and the LCD display will show
Copyright © Itech Electronic Co., Ltd.
Basic Operation
icon is displayed on the