El2084, El2088 - Technical Data - Beckhoff EL2124 Documentation

Digital output terminals
Table of Contents

Advertisement

2.6.1

EL2084, EL2088 - Technical data

Technical data
Number of outputs
Load type
Nominal voltage of the outputs
Output current max. per channel
Current consumption from load voltage
Supply voltage for electronic
Current consumption via E-bus
Electrical isolation
Bit width in the process image
Configuration
Weight
Permissible ambient temperature range dur-
ing operation
Permissible ambient temperature range dur-
ing storage
Permissible relative humidity
Dimensions (W x H x D)
Mounting [} 72]
Vibration/shock resistance
EMC resistance burst/ESD
Protection class
Installation position
Approval
EL20xx, EL2124
EL2084
4
ohmic, inductive, lamp load
24 V
(-15% / +20%)
DC
max. 0.5 A (short-circuit-proof)
typ. 30 mA + load
via the E-Bus
typ. 100 mA
500 V (E-bus/field voltage)
4 output bits
no address setting, configuration via TwinCAT System Manager
approx. 70 g
0°C ... + 55°C
-25°C ... + 85°C
95%, no condensation
approx. 15 mm x 100 mm x 70 mm (width aligned: 12 mm)
on 35 mm mounting rail conforms to EN 60715
according to EN 60068-2-6/EN 60068-2-27,
see also Installation instructions for terminals with increased mechanical load capacity
[} 74]
conforms to EN 61000-6-2 / EN 61000-6-4
IP20
variable
CE
cULus [} 150]
ATEX [} 81]
Version: 5.2
Product overview, digital output terminals
EL2088
8
max. 0.5 A (total current 3 A)
typ. 110 mA
8 output bits
0°C ... + 55°C
(aligned in horizontal installation position)
0°C ... + 45°C
(all other installation positions,
see Note [} 78])
see note [} 78]
55

Hide quick links:

Advertisement

Table of Contents
loading