General Description

2
The SARGENT Profile Series v.S1 exit device is available with either an HID
iCLASS
technology reader. It utilizes existing infrastructure and IEEE 802.3af PoE (Power over Ethernet)
®
technology as a proven alternative to traditional access control installations. The v.S1 is a self-contained mi-
croprocessor-controlled access control product with non-volatile memory. It uses the existing network cable
to communicate with access control systems. The v.S1 lock holds a total of 2400 unique users per lock.
Using PoE technology coupled with third party software, this v.S1 online exit device offers a complete, inte-
grated access control system.
The Profile Series v.S1 Exit Device may be used for both indoor and exterior applications. A weather-
protective gasket is recommended for exterior applications.
HID and iCLASS are registered trademarks of HID Global Corporation

Hardware Specifications

3
Profile Series Rim Exit Device
Latch – 3/4" throw, stainless steel
Accepts all SARGENT rim cylinders (8877 only)
Key retracts latch (8877 only)
Profile Series Mortise Exit Device
Latch – 3/4" throw, anti-friction, brass
Accepts all SARGENT mortise cylinders
(8977 only)
Key retracts latch (8977 only)

Electronic Specifications

4
2400 users per lock; 10,000 event audit trail
Multiple time zone and holiday
access scheduling
Centralized lock management
Real time door status monitoring
Supports HID
iCLASS
credentials (26 - 39 bit); supports CSN
®
reads for other common 13.56 MHz cards, in-
cluding MiFare, DesFire, and Felica
Installation
5
Wiring Overview
125 kHz prox or 13.56 MHz
®
A. PoE frame harness assembly
B. PoE data hinge from McKinney
(patent pending)
C. PoE door harness* from McKinney
D. DPS: Door Position Switch
(Cylindrical and Exits only)
E. Profile Series v.S1 PoE Lock
* Door width determines length
Profile Series Rim and Mortise Exit Devices
• Push bar retracts latch from inside
• Fire stop provided on all lever handle designs
• Profile Series exit devices furnished for
1-3/4" and 1-3/8" doors
• UL Listed
• Available in ET lever handle designs only
• First-In unlock configuration, either by time
or by user (selectable)
• Lock down capable
• Input Power: PoE Class 2 Device, as defined
by IEEE 802.3af
Supplied by Others
Network Cable
Network Switch (802.3af)
A
B
1-800-810-WIRE • www.sargentlock.com • A7765C
125 kHz prox or 13.56 MHz
®
Surface Mount RJ45
C
D
E