Assa Abloy Sargent Profile Series Installation Instructions Manual page 25

Poe exit device
Hide thumbs Also See for Sargent Profile Series:
Table of Contents

Advertisement

Profile Series v.S1 PoE Exit Device
Step #10 – Connect and Position Outside Escutcheon Wires
Images shown represent installation without gasket. If gasket is necessary, refer to Step #9.
Before the controller is attached to the door:
1. Attach the reader assembly ribbon cable to the inside face of the controller assembly (side that faces
towards the door when mounted (P1).
2. Attach the antenna cable to the inside face of the controller assembly (P2).
3. Attach the ground harness to the bottom of the controller assembly (E1).
2
(iCLASS only)
Outside Escutcheon
Step #11 – Connect Ground Wire Harness
Attach the ground harness:
1. Attach one leg of the ground harness to
bottom left screw of the controller assembly.
2. Attach the other leg of the ground harness to
the spade connector that was routed through
the top hole in the chassis in Step 4, #2
(Fig 4B Detail).
3. There is an unused ground terminal
attached to the harness from the chassis.
Outside of Door
Ground Wire
Harness
3
1
Reader Cable
Antenna
Fig. 10A
Fig. 11A
Ground Ring
Terminal
(2) 4-Pin
Connectors
From Hinge
1
Reader
Cable
2
Antenna
(iCLASS
Only)
Ground
Wire
Harness
3
2
Fig. 5B
1-800-810-WIRE • www.sargentlock.com • A7765C
Inside of Door
P1
1
2
P2
3
3
Reader Cable
Antenna
(iCLASS
Only)
1
Ground Wire
Harness
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sargent v.s1 series

Table of Contents