Profile Series v.S1 PoE Exit Device
Step #7 – Door Options
A. Fire Stop Plate (P/N 52-0033)
Fire-rated doors require a fire stop plate on
the outside of the door (Fig.7A).
1. If not present, drill (2) 1/8" x 1-1/4" deep
holes in the door.
Refer to template for fire-stop
prep locations.
2. Attach fire stop plate with flap up and out
using (2) #8 x 1/2" self-tapping screws
for wood and metal doors.
B. Weather Conduit (52-2847)
Install weather conduit on
exterior doors only (Fig. 7B).
1. Carefully insert the weather conduit into the
ribbon cable hole on the inside of the door.
2. Place the O-ring around the weather conduit
on the outside and up against the door (Fig. 7C)
Step #8 – Install Door Position Switch (DPS)
If it isn't installed, install the door position switch:
1. Prepare door according to proper template (A7990).
2. Insert DPS into the raceway on the latch edge pf the
door by pushing wires down raceway towards the lock.
Note: Use collar ONLY when installing in a METAL door.
3. Push DPS firmly in place by hand.
Note: DO NOT TAP SWITCH WITH ANY TOOL.
4. Connect DPS to adapter that plugs into TB2.
Refer to diagrams in the wiring steps,
beginning with Step #10.
NON FIRE-RATED
Outside of Door
Fig. 7A
Pull Out Slack
Route DPS
through door
Fig. 8A
1-800-810-WIRE • www.sargentlock.com • A7765C
Ribbon Cable Hole
Fig.7B
O-Ring
Fig.7C
Inside of Door