3 – Secure Inside Trim and Chassis
1. Route ET harness through wire run channel for wood doors (Fig. 3A)
and through access hole for metal doors (not shown).
Note: Make sure no wires are pinched.
2. Before securing chassis, connect ground wire harness:
a. Spade connector of ground ring terminal wire fits
through the hole (beneath the top screw) in the
chassis and connects to lug on ground
harness (Fig. 3B Detail).
b. Route the ground ring terminal and secure
through the top center hole with the top
1/4-20 x 2-3/8" flat head machine
screw (Fig. 3B Detail).
3. Engage ET spindle in the hub of exit
device chassis.
4. Secure chassis and ET with (2) 1/4-20 x
2-3/8" flat head machine screws.
5. Connect ET harness and connector
from chassis (Fig. 3C).
Fig. 3B Detail
Route wires under exits
chassis, and out wire route slot
14
1-800-810-WIRE • www.sargentlock.com • A7765C
Terminal
Inside of Door
4
2b
2a
Outside of Door
Profile Series v.S1 PoE Exit Device
Ground
Ring
Unused
5
1
3
Showing Wood Door Template
Ground Harness
2
Lug and Spade
Connector
Fig. 3A
Ground Ring
Terminal
(Unused)
4
Fig. 3C
With Cylinder Hole