Assa Abloy Sargent Profile Series Installation Instructions Manual page 18

Poe exit device
Hide thumbs Also See for Sargent Profile Series:
Table of Contents

Advertisement

Step #11 – Additional Wiring Connections
Chassis, DPS and raceway wire connections:
1. Connect RX rail connector from ET
to chassis harness.
2. Attach connector from ET
to the controller assembly (TB1).
Tuck ferrite bead under circuit board.
3. Connect DPS from switch to
2-pin connector of the harness
connected to controller
assembly (TB2).
4. Route the two connectors
from the raceway over the
controller assembly, through the
gap between the plastic control-
ler assembly and
the escutcheon, to the front
of the circuit board.
Step #12 – Connect and Position Circuit Board Wires
Raceway cables and ground attach to front of circuit board.
Turn the escutcheon containing the controller assembly over:
1. Route the raceway connectors over the top of the controller assembly
and plug into the front of the circuit board (side that faces out when
mounted (J7, J4; Fig. 12A).
2. Route the 2 ground ring terminals, one from the lock and the other
from the hinge wiring, over the top of the controller assembly and con-
nect both to the top escutcheon screw.
Note: Connectors go on only one way.
Do not offset connectors and make sure they are completely seated.
18
1-800-810-WIRE • www.sargentlock.com • A7765C
3
Fig. 11A
Profile Series v.S1 PoE Exit Device
Ground Ring Terminal
4
(2) 4-Pin Connectors
From Hinge
2
1
Unused
Fig. 12A
Inside of Door
P1
P2
2
TB1
Ferrite
Bead
Unused
3
DPS
2
Ground
Ring
Terminal
1
Front

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sargent v.s1 series

Table of Contents