7.4.7

Replacing a 2.5-inch backplane

Field Replaceable Unit
(FRU)
Tools: Phillips PH2 / (+) No. 2 screw driver
7.4.7.1

Preliminary steps

I
The HDD backplane is mounted on the HDD cage. It is not necessary to
remove the HDD cage before installing or removing the HDD backplane.
"Locating the defective server" on page 47
Ê
"Shutting down the server" on page 49
Ê
"Disconnecting the power cord" on page 50
Ê
"Getting access to the component" on page 51
Ê
"Removing the HDD fan module" on page 165
Ê
Ê Release all HDD/SSD modules and pull them out a few centimeters, see
section
"Removing 2.5-inch HDD/SSD modules" on page
I
The HDD/SSD modules need not to be removed. But if you want to
remove them nevertheless, check if all HDD/SSD modules are
uniquely identified so that you can reinsert them into their original
bays.
Ê Release all dummy modules and pull them out a few centimeters, see
section
"Removing a 2.5-inch HDD/SSD dummy module" on page
7.4.7.2

Removing a 2.5-inch HDD/PCIe backplane

I
The following description is valid for:
– An HDD backplane
– A PCIe backplane
I
Configurations with up to four 2.5-inch HDDs/SSDs, there is either one
HDD backplane or one PCIe backplane.
TX1320 M4
Hard disk drives (HDD) and solid state drives (SSD)
Upgrade and Maintenance Manual