Removing The M.2 Ssd; Preliminary Steps - Fujitsu PRIMERGY TX1320 M4 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY TX1320 M4:
Table of Contents

Advertisement

System board and components
I
The M.2 SSD can be used only for boot device. Do not use VMFS on the
M.2 SSD because of not meeting required endurance. For more
information, see the VMware Knowledge Base 2145210.
http://kb.vmware.com/s/article/2145210
I
For Japan
In order to setup the ESXi, see the corresponding version of the "VMware
vSphere Software Description" from the following URL and reinstall ESXi
to the M.2 SSD.
http://jp.fujitsu.com/platform/server/primergy/software/vmware/manual/

14.5.2 Removing the M.2 SSD

Upgrade and Repair Unit
(URU)
Tools: – Phillips PH1 / (+) No. 1 screw driver
– Hexagon screw driver (for moving the screw to another hexagon
stand-off)

14.5.2.1 Preliminary steps

"Shutting down the server" on page 49
Ê
"Disconnecting the power cord" on page 50
Ê
"Getting access to the component" on page 51
Ê
Ê If applicable,
"Removing expansion cards" on page
Ê If applicable, remove the HDD fan module 2.5-inch HDD variant, see section
"Replacing the HDD fan module" on page
Ê If applicable, disconnect the Oculink cables from the PCIe backplane.
Ê If applicable, disconnect the SATA cable of the ODD from the system board.
292
Upgrade and Maintenance Manual
Hardware: 5 minutes
187.
164.
TX1320 M4

Advertisement

Table of Contents
loading

Table of Contents