General Technical Details - Beech ovens E Series Installation And Operation Manual

Table of Contents

Advertisement

Beech Ovens
E-Series Manual (R4)

General Technical Details

The data plate mounted on the inside of the lower access door contains the specific
information for your oven. The following information is general technical details for all
ovens and related Gas types, based on an 80Mj Gas Burner.
Gas Pressure at
Burner Injector
Gas Pressure at
Isolating Valve
Gas
Consumption per
Hour (approx.)
Timber
consumed
Hardwood, no
Gas Lunch and
Dinner
Secondary air for
Gas Burner
(Equivalent to a 40cm x
40cm vent under the oven
floor)
Air Conditioning
Heat Load
The following table shows the correct jet orifice size for the standard Beech Ovens
gas burners.
Gas output (Mj)
30Mj
40Mj
50Mj
60Mj
70Mj
80Mj
Page 56
Natural
2.65kPa
1kPa (High)
1.0kPa (Min)
2.65kPa (Min)
5.0kPa (Max)
5.0kPa (Max)
2.0 m³/ Hr
0.6 m³/ Hr
0.1 m³/ day
5.66 litres/sec
<2kW Heat Load
Natural Gas
2.45mm
2.95mm
3.20mm
3.60mm
3.90mm
4.10mm
Confidential and Proprietary
ULPG
(High)
ULPG
1.60mm
1.85mm
2.10mm
2.30mm
2.50mm
2.60mm
2/09/2019 (C)