Ce Specifications - Beech ovens E Series Installation And Operation Manual

Table of Contents

Advertisement

Beech Ovens
E-Series Manual (R4)

CE Specifications

The following table outlines the technical details for ovens installed within the CE
region.
Country
Category
DE
I2ELL
AT, DK, EE, FI,
IT, LT, NO, PT,
RO, SE, SK, TR,
I2H
BG, CH, CY, CZ,
ES, GB, GR, IE,
SI
BE
I2E(R)
FR
I2Er
NL
I2L
HU
I2H
CH, DE, NL,
I3P
FR, ES
FR, LU, CH, CZ,
GB, GR, IE, SI,
I3P
BR, ES, BE, PT,
SK, PL
Timber Consumption:
Hardwood
Airflow required:
Duct Size: Natural Draft
Duct Size: Fan assisted
Duct Material:
Secondary Air for gas
burner:
Air conditioning Heat
Load:
Electrical Data:
Page 58
Natural Gas
Nominal
Heat Input
Pressure
G20: 22kW
20mBar
G25: 19kW
20mBar
G20: 22kW
20/25mBar
G20: 22kW
20/25mBar
G20: 22kW
25mBar
G25: 22kW
25mBar
G20: 22kW
ULPG
50mBar
G31: 18.5kW
37mBar
G31: 18.5kW
Note: CH, FR and ES allow both 37 and 50mBar
450 litres / sec. Suction controlled by system damper. (Direct connect)
300mm square (900cm²) or equivalent area round.
300mm square (900cm²) or equivalent area round.
1.2mm galvanised or 0.9mm stainless steel (As per local regulation)
6 litres / sec (approximately)
220-240 Volts 50 Hz ac 10 Amp supply with earth
Confidential and Proprietary
Nominal
Rate
2.3m ³/Hr
3.5mm (28 gauge)
2.3m ³/Hr
3.5mm (28 gauge)
2.3m ³/Hr
3.5mm (28 gauge)
2.3m ³/Hr
3.5mm (28 gauge)
2.3m ³/Hr
3.5mm (28 gauge)
2.3m ³/Hr
3.5mm (28 gauge)
1.44kg /Hr
2.2mm (44 gauge)
1.44kg /Hr
2.2mm (44 gauge)
³
0.1m
/ day
<2 kW heat load
2/09/2019 (C)
Injector
Diameter