Message

FORMAT ERROR

Meaning
A subroutine input is either missing or the value entered
is incorrect.
Action
Correct the subroutine input line then run again.
This is a reset condition.
Message

ACTIVE BEAM CUT

Meaning
The receiver is registering a cut beam signal at the start
of a measuring move. This may be due to the tool, swarf
or coolant interfering with the beam.
Action
Correct the error then try again.
This is a reset condition.
Message

BEAM NOT CUT

Meaning
The receiver has not registered a beam cut condition
during the measuring move, possibly because the tool is
missing or the measuring distance is insufficient to reach
the beam. This may be due to bad subroutine input data
or failure to properly calibrate the probe system.
Action
Correct the error then try again.
This is a reset condition.
Message
RPM OUT OF RANGE <800
Meaning
The value entered in the R19=s input is less than the
minimum value of 800 rev/min.
Action
Correct the subroutine input line then run the subroutine
again.
This is a reset condition.