Installing The Software; Subroutine Parameters; Parameter Store For Calibration Data - Renishaw NC1 Programming Manual

Non-contact tool setting system
Table of Contents

Advertisement

Installing the software

Installing the software
Before installing the NC1 software, read the guidelines contained in
the Readme file on the software floppy disk.

Subroutine parameters

The following parameters are used by the NC1 system software:
'RENT' global parameters – used for the calibration data and
n
settings data.
Global parameters RENC[0] to RENC[49] – used for the settings
n
data.
Local parameters RENL[1] to RENL[32] – used for locally defined
n
data.
Global parameters R01 to R26 – used for subroutine inputs.
n

Parameter store for calibration data

The following parameters are set automatically during the calibration
cycles.
RENT[20]
Z-axis position of the beam, when measured from the
positive side of the beam.
RENT[21]
(Reserved)
RENT[22]
X or Y-axis position of the beam, when measured from
the negative side of the beam.
RENT[23]
X or Y-axis position of the beam, when measured from
the positive side of the beam.
12