RENC[10] = –800.0 Maximum length tool
RENC[11]= –950.0
Relative to a master tool with zero (0) tool-
offset value.
The master tool-offset register is set to zero (0) and all other tool-
offset registers are set as ± values relative to the master tool.
Example
Home position, to the zero (0) position of the part
program = –1000 mm (but this is not important)
A master calibration tool of 150 mm is used (offset register
value = 0).
The longest tool for the machine is 200 mm long.
The shortest tool for the machine is 50 mm long.
Parameters RENC[10] and RENC[11] must be set in the Setting-data
subroutine (L9760). Set them as follows:
RENC[10] = 50.0
RENC[11] = -100.0