Alarms; Examples; Tool Radius Setting 1 - Renishaw NC1 Programming Manual

Non-contact tool setting system
Table of Contents

Advertisement

Outputs
The following outputs are set or updated when this cycle is executed:
Set tool radius/diameter
RENC[48]
Out of tolerance flag. This is set when the measured
tool length is out of tolerance, provided the R11=h input
is used.
(1 = Out of tolerance, 0 = In tolerance)

Alarms

The following alarms may be generated when this cycle is executed.
FORMAT ERROR
OUT OF TOLERANCE
RPM OUT OF RANGE
For an explanation of the meaning of alarms, see "Error messages
and alarms" on page 85.

Examples

Tool radius setting 1

Assume the tool is a 10 mm (0.394 in) diameter slot drill.
%_N_????
T1
M6
L9800
Tool radius/diameter setting
47