Oracle Sun Blade 6000 Product Notes

Ethernet switched nem 24p 10gbe release 1.2.2
Table of Contents

Advertisement

Quick Links

Sun Blade 6000 Ethernet Switched NEM
24p 10GbE Release 1.2.2 Product Notes
Part No: E26764-08
March 2016

Advertisement

Table of Contents
loading

Summary of Contents for Oracle Sun Blade 6000

  • Page 1 Sun Blade 6000 Ethernet Switched NEM 24p 10GbE Release 1.2.2 Product Notes Part No: E26764-08 March 2016...
  • Page 3 Oracle. Oracle Corporation and its affiliates will not be responsible for any loss, costs, or damages incurred due to your access to or use of third-party content, products, or services, except as set forth in an applicable agreement between you and Oracle.
  • Page 4 Oracle Corporation et ses affiliés déclinent toute responsabilité ou garantie expresse quant aux contenus, produits ou services émanant de tiers, sauf mention contraire stipulée dans un contrat entre vous et Oracle. En aucun cas, Oracle Corporation et ses affiliés ne sauraient être tenus pour responsables des pertes subies, des coûts occasionnés ou des dommages causés par l’accès à...
  • Page 5: Table Of Contents

    Contents Using This Documentation .................  7 Product Documentation Library .................  7 Feedback .......................  7 Sun Blade 6000 Ethernet Switched NEM 24p 10GbE Release 1.2.2 Product Notes ........................ 9 NEM Documentation Reading Order .............. 9 Introducing What's New in Release 1.2 .............  10 IPv6 Switching and Routing .............. 10 ONET Protocol ..................
  • Page 6 Unlit Link and Activity LEDs for the SFP+ Ports (6873825) ...... 39 The switch Command Line Option Is Unsupported ........ 39 SSL V3.0 POODLE DISABLE SSL V3 (19842641) ........ 39 Sun Blade 6000 Ethernet Switched NEM 24p 10GbE Release 1.2.2 Product Notes • March 2016...
  • Page 7: Using This Documentation

    Using This Documentation Overview – Contains important late-breaking information about this release of Oracle's Sun ■ Blade 6000 Ethernet Switched NEM 24p 10GbE Audience – Technicians, system administrators, and authorized service providers ■ Required knowledge – Advanced experience troubleshooting and replacing hardware ■...
  • Page 8 Sun Blade 6000 Ethernet Switched NEM 24p 10GbE Release 1.2.2 Product Notes • March 2016...
  • Page 9: Sun Blade 6000 Ethernet Switched Nem 24P 10Gbe Release 1.2.2 Product Notes

    Read the documentation in this order. Step Document Title or Type Information Provided Sun Blade 6000 Ethernet Switched NEM 24p 10GbE Late-breaking information, supported Release 1.2.2 Product Notes configurations, and system limitations Sun Blade 6000 Ethernet Switched NEM 24p 10GbE Release 1.2.2 Product Notes...
  • Page 10: Introducing What's New In Release 1.2

    IPv6 address sizes. Refer to the Sun Ethernet Fabric Operating System OSPFv3 Administration Guide for more information about this feature. Routing Information Protocol Next Generation ■ Sun Blade 6000 Ethernet Switched NEM 24p 10GbE Release 1.2.2 Product Notes • March 2016...
  • Page 11: Onet Protocol

    Ethernet frames can endlessly circulate. STP can logically break such loops and prevent looping traffic from clogging the network. The dynamic control of the topology provides continued network operation in the presence of redundant or unintended looping paths. Sun Blade 6000 Ethernet Switched NEM 24p 10GbE Release 1.2.2 Product Notes...
  • Page 12: Server Load Balancer

    Load distribution policies are based on the contents of the L3/4 packet header. Failover is supported at the server member's level. A failed member Sun Blade 6000 Ethernet Switched NEM 24p 10GbE Release 1.2.2 Product Notes • March 2016...
  • Page 13: Oracle Ilom 3.0 Features

    LLA is only supported when the switch is running a Layer 2 configuration. LLA is Sun Blade 6000 Ethernet Switched NEM 24p 10GbE Release 1.2.2 Product Notes...
  • Page 14: Supported Configurations, Operating Systems, And Required Patches

    Supported Configurations, Operating Systems, and Required Patches This table lists the server modules (blades) and FEMs that are supported in a Sun Blade 6000 modular system or Sun Netra 6000 modular system chassis. In these product notes, the term "modular system" refers to both the Sun Blade 6000 Note - modular system chassis and the Sun Netra 6000 modular system chassis.
  • Page 15: Required Firmware And Kernel Drivers

    ■ Modular System Limitations These limitations apply to the NEM when installed in a Sun Blade 6000 modular system or Sun Netra 6000 modular system chassis. This NEM cannot be installed in a modular system chassis with any other type of NEM. If ■...
  • Page 16: Enabling Sas2 Functionality

    Supported Server Modules and REMs This table lists the server modules and associated REMs that are supported for use with the Sun Blade 6000 Ethernet Switched NEM 24p 10GbE. Sun Blade 6000 Ethernet Switched NEM 24p 10GbE Release 1.2.2 Product Notes • March 2016...
  • Page 17: Minimum Required Software

    A SAS2-enabled NEM must be installed in the chassis to enable a server blade to be zoned with storage devices on a storage blade. At this time, zoning of SAS2 external ports on the NEM is not supported. For information on setting up storage zoning, refer to the Oracle ILOM 3.0 documentation.
  • Page 18: Back Up The Current Configuration Before Upgrading

    If a syslog server address was configured in Oracle ILOM, the address is not preserved (see CR 7022286), and you must reconfigure the syslog server setting after the upgrade or restore.
  • Page 19 SEFOS(config)# SEFOS(config)# Save the current configuration for restoration. write startup-config SEFOS# Copy the configuration file to a remote location. SEFOS# copy startup-config tftp://12.0.0.100/switch.conf Exit and restart the NEM. Sun Blade 6000 Ethernet Switched NEM 24p 10GbE Release 1.2.2 Product Notes...
  • Page 20: Download The Nem Firmware Package

    Under the Patch Search section, select Product or Family (Advanced Search). Type nem in the Product field and select Sun Blade 6000 10GbE Switch NEM. Select the down arrow in the Release field and select the Sun Blade 6000 10GbE Switch NEM folder.
  • Page 21: Upgrade The Nem Firmware

    “Back Up the Current Configuration Before Upgrading” on page Ensure that you have a network configuration in place on the NEM. For more information, refer to the Sun Blade 6000 Ethernet Switched NEM 24p 10GbE User's Guide. (Optional) If you have not restarted the NEM as part of backing up the configuration, restart the NEM now.
  • Page 22 /SP -> Are you sure you want to reset /SP (y/n)? Performing reset on /SP If the upgrade was done while in ONET mode, you must explicitly restart ONET from Oracle ILOM after the upgrade as follows: start /NEM/onet ->...
  • Page 23: Enable Or Disable Sas2 From Oracle Ilom

    /CH/NEMx command (where x is the NEM's slot number) from the CMM level. Display the current SAS2 status. -> cd /NEM/SAS/ /NEM/SAS /NEM/SAS-> Targets: Properties: type = SAS Expander sas_status = disabled Commands: Sun Blade 6000 Ethernet Switched NEM 24p 10GbE Release 1.2.2 Product Notes...
  • Page 24 -> Disabling the device will take approximately 2 minutes... stop: SAS Disabled successfully. -> /NEM/SAS Targets: Properties: type = SAS Expander sas_status = disabled Commands: Sun Blade 6000 Ethernet Switched NEM 24p 10GbE Release 1.2.2 Product Notes • March 2016...
  • Page 25: Configure 1Gbps Mode On Sfp+ Interfaces

    Refer to the Sun Ethernet Fabric Operating System CLI Base Reference Manual for details. Sun Blade 6000 Ethernet Switched NEM 24p 10GbE Release 1.2.2 Product Notes...
  • Page 26 Vlan Port configuration table ------------------------------- Port Ex0/3 Port Vlan ID Port Acceptable Frame Type : Admit Only Vlan Tagged Port Ingress Filtering : Enabled Port Mode : Hybrid Sun Blade 6000 Ethernet Switched NEM 24p 10GbE Release 1.2.2 Product Notes • March 2016...
  • Page 27: Managing Sefos Configurations

    ■ Include the SEFOS Configuration in Backups By default, only the Oracle ILOM configuration is backed up when the backup feature is used. Complete the following tasks to include the SEFOS configuration in this backup. Before backing up your SEFOS configuration using the Oracle ILOM backup feature, complete the following steps: a.   ...
  • Page 28: Restore The Configuration

    Load successful. If DHCP is used for network configuration, the DNS setting is overwritten with values Note - supplied by the DHCP server upon restoration. Sun Blade 6000 Ethernet Switched NEM 24p 10GbE Release 1.2.2 Product Notes • March 2016...
  • Page 29: Configuring Tacacs

    Disabled † In the TACACS+ server, the combination of ppp and ip can be configured to send additional fields in packet data. For Oracle ILOM clients this is used to send Oracle ILOM-specific fields like sefos-fs-privilege and ilom-role. Sun Blade 6000 Ethernet Switched NEM 24p 10GbE Release 1.2.2 Product Notes...
  • Page 30: Configure Tacacs+ Settings

    Issues Corrected in the Patch Update These issues have been corrected in this update. Issue Number Description of Corrected Issue 22543509 Fix for CVE-2015-5600 Bug 22686043. Fix for CVE-2015-3197. Sun Blade 6000 Ethernet Switched NEM 24p 10GbE Release 1.2.2 Product Notes • March 2016...
  • Page 31: Issues Corrected In Prior Updates

    A session's state is not cleaned up in SEFOS when remotely authenticated sessions exit. 17435883 Remotely authenticated user removed from SEFOS prematurely. 17435892 QSFP MMF transceiver and QSFP Cu Twinax cables are not recognized by SEFOS. Sun Blade 6000 Ethernet Switched NEM 24p 10GbE Release 1.2.2 Product Notes...
  • Page 32 2198812 SEFOS MIB access is lost due to the Agentx subagent dropping packets. 6899100 Garbage characters are displayed with backspace key at the login prompt. Sun Blade 6000 Ethernet Switched NEM 24p 10GbE Release 1.2.2 Product Notes • March 2016...
  • Page 33 RIP packets should not be trapped if the RIP feature is disabled. 7080854 Creating a user with the string password displays an internal password in Oracle ILOM. 7080860 Unable to create a user in Oracle ILOM starting with the string password.
  • Page 34 6964907 64-bit counters in interface MIB are not working. 6966581 Oracle ILOM restore from the telnet console restarts the session and the user can't login again. 6966772 Oracle ILOM restore from BUI restarts the session and user can't login again.
  • Page 35: Known Issues

    6993790 Email-alert is not working. 6994351 When a RADIUS user has an Oracle ILOM role of aucr, the show command in Oracle ILOM does not work properly on the switch. 6996351 Need the remote IP address to be included in Oracle ILOM logging.
  • Page 36: Slb-L2 Error Is Seen When Reassigning A Port From One Lbg Group To Another (7100720)

    SLB L2 Cannot Create More Than Two Groups, SLB L2 Limits to Two LBGs (7092380) There is no workaround for this issue. Sun Blade 6000 Ethernet Switched NEM 24p 10GbE Release 1.2.2 Product Notes • March 2016...
  • Page 37: Manually Deleting Static Route Does Not Affect The Corresponding Slb Entry (7064092)

    The NEM does not fully adhere to the University of New Hampshire (UNH) IGMPv3 Conformance Test Suite. Workaround: No workaround is available. If you experience a suspected IGMP interoperability problem or other issue with the NEM, contact your authorized Oracle service provider. Ports Lock and Corresponding LEDs Stay Lit or...
  • Page 38: Qos - Set Algo-Type Taildrop Queue-Drop-Algo Does Not Work (6991230)

    Workaround: Clear the fault each time the NEM or the CMM is rebooted. -> set /CH/NEM0/ clear_fault_action=true Are you sure you want to clear /CH/NEM0 (y/n)? y Set 'clear_fault_action' to 'true' Sun Blade 6000 Ethernet Switched NEM 24p 10GbE Release 1.2.2 Product Notes • March 2016...
  • Page 39: Using Vlan 1 As Shown In Various Examples In The Documentation Generates Error Codes (6968484)

    Output examples that show a single instance are valid in SEFOS. SSL V3.0 POODLE DISABLE SSL V3 (19842641) Workaround: Disable SSLv3 from ILOM under /SP/service/https. cd /SP/services/https -> /SP/services/https Sun Blade 6000 Ethernet Switched NEM 24p 10GbE Release 1.2.2 Product Notes...
  • Page 40: Sun Blade 6000 Ethernet Switched Nem 24P 10Gbe Release 1.2.2 Product Notes • March

    -> /SP/services/https Targets: Properties: port = 443 servicestate = enabled sslv2 = disabled sslv3 = disabled tlsv1 = enabled weak_ciphers = disabled Commands: show Sun Blade 6000 Ethernet Switched NEM 24p 10GbE Release 1.2.2 Product Notes • March 2016...