Earthing the CPV valve terminal

For earthing purposes, all variants of the CPV valve terminal
have an earthing connection. This is on the left−hand end
plate (see diagram).
1
Please note
Earth your CPV valve terminal.
Connect the earth connection on the left−hand end plate
·
(see Fig. 2/5) with low impedance (short cable with large
cross−sectional area) to the earth potential.
Tighten the earthing screw with max. 1 Nm.
·
In this way, you will avoid interference caused by electro
magnetic influences.
3−17