5. Maintenance and conversion
Festo P.BE−CPV−EN en 0503g

Fitting the CPV valve terminal

CPV valve terminal with pneumatic multipin
In this case, place the 3−piece and 4−piece seals in the
·
recesses in the left or fight−hand end plate. Press the
2−piece seals carefully into the threads in the work con
nections.
Place the CPV valve terminal on the pneumatic multipin
·
and tighten the fastening screws in the left and right−hand
end plates in diagonally opposite sequence with 0.3 Nm.
Tighten the screws in diagonally opposite sequence with
2 Nm (CPV10/14) or 4 Nm (CPV18).
With floor mounting
In this case, insert the fastening screws into the right−
·
hand end plate and tighten the valve terminal.
Fitting onto a wall or hat rail
Fasten the right−hand wall fitting to the wall with two M4
·
screws or tighten the right−hand hat rail clamping unit.

Fitting the pneumatic and electrical connections

Fit the connections (see chapter 3).
·
5−15