3. Installation
Festo P.BE−CPV−EN en 0503g
Vacuum generator plates
Please note
A high back pressure in exhaust channel 3/5 will impair
the functioning of the vacuum generator.
Make sure that there is optimal exhausting.
·
If the CPV valve terminal is fitted with valve sub−bases and
vacuum generator plates, the exhaust air from the valve
sub−bases (in channel 3/5) can influence the vacuum gen
eration.
In this case, separate exhaust channel 3/5 between the
·
vacuum generator plates and the valve sub−bases by
means of the separator plate with Ident. code S.
Connect the work lines to the vacuum generator plate:
Vacuum valve sub−base with Ident. code A:
Connect the vacuum suction nozzle to work connection 4.
·
Seal work connection 2 with a blind plug.
·
Vacuum valve sub−base with Ident. code E:
Connect the vacuum suction nozzle to work connection 4.
·
Connect work connections 2 and 4 together with tubing or
·
with vacuum valve extension CPV..−BS−GRZ−V... .