3.3.5 Motor running speed
The running speed of the motor is displayed in RPM unit. The changes of the speed cannot be seen du
e to inner filtering process. (To view the speed changes, use the monitor output)
In case the motor is running clock wise, a '-' will be displayed.
; motor running speed
; minus rpm display (-1000rpm)
3.3.6 Absolute encoder multi turn pulse
Displays the running count of the absolute encoder inside the motor. (1 count per rotationt)
When the count exceeds 8191, it will resume to '0'.
; absolute encoder running speed count
3.3.7 Absolute encoder single turn pulse
Displays the pulse count per rotation of the absolute encoder. (8192 count per rotation)
When the count exceeds 8191, it will resume to '0'.
; absolute encoder pulse count per rotation
3.3.8 Effective load ratio
The effective load is displayed in %. If the ratio is in the minus, a '-' will be displayed and it will resume
to
'0' when the SVON signal is OFF.
3.3.9 Maximum load ratio
The maximum load is displayed in %. While the SVON signal is ON, it will always display the maximum
ratio and to resume to '0', press the operator SET key. If the ratio is in the minus, a '-' will be displaye
d and it will resume to
; maximum load ratio
; minus ration display (-250%)
; effective load ratio
; minus ratio display (-100%)
'0' when the SVON signal is OFF.
display range [-3000 ~ 3000]
display range [0 ~ 8191]
display range [0 ~ 8191
display range [-300.0 ~ 300.0]
display range [-300.0 ~ 300.0]