Doosan Vision DVSD-TA Series Operation Manual page 51

Ac servo motor / drive
Table of Contents

Advertisement


3.6.2 Parameter list
N0. Abbr.
motor power capacity
00
MPC
motor running direction
01
MRD
reserve parameter
02
-
fixed direction, jog function selection
03
JFS
encoder pulse per one rotation
04
EPR
maximum POST number
05
MPN
06
GR1
gear ratio - motor side
07
GR2
gear ratio - machine side
POST number of home
08
HSP
alternate angle (only TT1500, TT1800)
09
TCO
10
PKP
position loop proportional gain
11
VKP
speed loop proportional gain
12
VKI
speed loop integral gain
servo ready on delay time
13
SROT
brake off control delay time
14
BFT
brake on delay time
15
BOT
16
VTO
monitor offset voltage
monitor selection
17
VTM
positioning complete range
18
INP
remaining pulse allowance
19
RPA
20
FFG
position loop feed-forward gain
21
FTC
feed-forward filter time constant
22
TLP1
positive torque limit 1
negative torque limit 1
23
TLN1
positive torque limit 2
24
TLP2
negative torque limit 2
25
TLN2
speed limit
26
VLS
27
JSP
jog speed at set home
28
VEL
operation speed
29
ATC
acceleration time
30
DTC
deceleration time
speed monitor output voltage
31
MRV
torque monitor output voltage
32
MRT
initial status display
33
ISD
34
AOL
encoder coordinates compensation (lower)
35
AOM
encoder coordinates compensation (upper)
36
HOL
set value of machine zero-point (lower)
37
HOM
set value of machine zero-point (upper)
38
IKP
current loop proportional gain
39
IKI
current loop integral gain
feedback pulse (lower)
40
FPL
feedback pulse (upper)
41
FPU
acceleration rate of remaining value
42
ACR
compensation of remaining value(lower)
43
REM_L
44
REM_H
compensation of remaining value(upper)
45
-
reserve parameter
override selection
46
OV_SEL
A
Adjusted parameter is only valid when power is off
B
You can adjust the parameters under the servo is off.
C
You can adjust the parameters under the servo is on.
You can never adjust the parameters for Maker management.
If you change this parameter, Drive will not operate properly.
D
Name
Note. Adjusted parameter operated as follows.
Range
Default
0
0
0 ~ 1
1
0
0
0 ~ 1
0
2048
2 ~ 127
12
POST
1 ~ 9999
33
1 ~ 9999
12
POST
1 ~ 127
1
0 ~ 1
0
0 ~ 2048
256
0 ~ 2048
250
0 ~ 2048
1
0 ~ 40
0
10 msec
0 ~ 40
0
10 msec
0 ~ 40
0
10 msec
-12 ~ 12
0
10/128 V
0 ~ 3
0
1 ~ 9999
100
PULSE
1 ~ 6000
6000
100 PULSE
0 ~ 100
0
0 ~ 100
0
4 msec
0 ~ 300
250
0 ~ 300
250
0 ~ 300
50
0 ~ 300
50
0 ~ 3000
1850
1 ~ 1000
100
10 ~ 3000
1800
0 ~ 340
50
0 ~ 340
80
500~ 5000
3000
2 mV
500~ 5000
1500
2 mV
0 ~ 10
6
0 ~ 2
0
on
DOOSAN SERVO
Uint
A
A
A
A
A
A
Rev
A
A
A
A
B
B
B
B
B
B
B
B
B
B
%
B
B
%
B
%
B
%
B
%
B
rpm
B
rpm
B
rpm
B
msec
B
msec
B
B
B
B
D
D
D
D
D
D
D
D
D
D
D
D
B
46