3.4.13 Setting machine home
▷
This function will set the current position to machine home. Press the SET key in the
zero-point setting mode for 10 seconds and the parameters dealing with zero-point will be
automatically set and displayed.
▷
After setting the zero-point, turn the power OFF and then turn it ON in order to complete
the setting.
⇩
SET
⇩
; Press the SET key for more than 10 sec.
It will save the parameters automatically.
; It will save the parameters automatically from 34 to 46.
⇘
;
After saving to 46, it will resume to initial mode.
DOOSAN SERVO
41