3.4.8 Position data output signal test
▷
This makes it possible to test the sequence or the connection by forcing the position data output
signal to be displayed externally.
⇩
SET
POSO_0 signal OFF
⇩
SET
⇩
POSO_7 signal OFF
⇩
SET
3.4.9 Manufacturer's management code
; This is the code managed by the manufacturer
3.4.10 Jog operation
▷
The drive self operates regardless of external signals.
▷
When setting the zero-point, use this to move the POST number to its initial position.
Press the UP or DOWN key and meanwhile the driver will rotate according to the fixed speed of
parameter 27.
⇩
SET
⇩
CW rotation
⇩
SET
; Press the SET key and set the output data.
⇦ ⇨
⇦ ⇨
Resumes to initial display
; Press the SET key and the SVON signal will automatically
turn ON, and it will change to Jog run mode.
; Jog run mode
CCW rotation
; Resumes to initial display mode
POSO_0 signal ON
POSO_7 signal ON
⇩
DOOSAN SERVO
39