Image Acquisition Controls - JAI GO-5100MP-USB User Manual

5.1m cmos digital progressive scan polarized camera
Table of Contents

Advertisement

Image Acquisition Controls

Perform operations and configure settings related to image acquisition in [AcquisitionControl].
The following acquisition modes are available on the camera.
AcquisitionMode
SingleFrame
MultiFrame
Continuous
Changing the Frame Rate
When [TriggerMode] is disabled, you can change the frame rate in [AcquisitionFrameRate].
Note
• The shortest frame period varies depending on the ROI, pixel format, and binning mode
selected. The longest frame period is 0.125 Hz (8 sec.).
• When TriggerMode[FrameStart] is enabled, the [AcquisitionFrameRate] setting is disabled.
Maximum Frame Rate
The maximum frame rate is the smaller value between the SensorFR that is calculated from
the readable range of the sensor and the InterfaceFR that is limited by the USB 3.0 bandwidth.
Maximum frame rate
(Value derived from sensor
scanning range)
SensorFR
Acquire a single frame when the [AcquisitionStart]
command is executed.
Acquire the number of frames specified in
[AcquisitionFrameCount] when the [AcquisitionStart]
command is executed.
Acquire images continuously until the
[AcquisitionStop] command is executed.
Compared
SensorFR < InterfaceFR
Maximum frame
SensorFR
Description
Maximum frame rate
(Value derived from USB 3.0
InterfaceFR
SensorFR > InterfaceFR
Maximum frame
InterfaceFR
— 30 —
GO-5100MP-USB
bandwidth)

Advertisement

Table of Contents
loading

Table of Contents