Advertisement

Pulse Generator Clear
Activation
Pulse Generator Clear Source
Pulse Generator Clear Inverter
Pulse Generator Clear Sync
Mode
Off,
Off
LevelHigh,
LevelLow,
RisingEdge,
FallingEdge
Low,
Low
High,
Acquisitiion Trigger Wait,
Frame Trigger Wait,
Frame Active,
Exposure Active,
FVAL,
LVAL,
User Output 0
User Output 1
Line5 - Opt In 1
NAND0 Out
NAND1 Out
True, False
False
Async Mode,
Async Mode
Sync Mode
— 55 —
Set the clear signal condition for the count
clear input of the pulse generator.
Select the count clear input signal source.
Select whether to invert the polarity of the
count clear input signal.
Select the sync mode for the count clear
input signal.