Item
h) ) equencer Control
Sequencer Mode
Sequencer Mode Select
Sequencer Configuration Mode
Sequencer Set Selector
Sequencer Frame Number
Sequencer Set Next
Sequencer Width
Sequencer Height
Sequencer OffsetX
Sequencer OffsetY
Sequencer Gain
Sequencer Exposure Time
Sequencer Black Level
Sequencer H Binning
Sequencer V Binning
Sequencer Repetition
Sequencer Set Active
Sequencer Command Index
Sequencer Set Start
Sequencer Reset
Setting range
Off, On
Off
Trigger Sequencer Mode,
Trigger Sequencer Mode
Command Sequencer Mode
Off, On
On
1〜128
1
1〜255
1
0〜128
16〜2464
2464
1〜2056
2056
0 〜 2448
0
0 〜 2055
0
100〜1600
100
1 〜 8000000
-133〜255
0
1,2
1
1,2
1
1〜255
1
1〜128
1
1〜128
1
1〜128
1
— 52 —
Default value
Configure sequencer settings.
Enable(On)/disable(Off) [SequencerMode].
Select the sequencer mode.
Select [On] to change the settings within
the index.
Select the index number to configure.
Set the number of frames to display for the
selected SequencerIndex.
(Enabled only for TriggerSequencer.)
Set the next index to be displayed for the
selected SequencerIndex.
(Enabled only for TriggerSequencer.)
If 0 is specified, the operation of Sequencer is
stopped.
Set the width of the selected
SequencerIndex.
Set the height of the selected
SequencerIndex.
Set the horizontal offset value for the
selected SequencerIndex.
Set the vertical offset value for the selected
SequencerIndex.
Set the GainAnalogAll value.
Set the exposure time for the selected
SequencerIndex.
Set the BlackLevelDigitalAll for the selected
SequencerIndex.
Set the H Binning for the selected
SequencerIndex.
Binning Horizontal Mode setting is applied in binning
mode.
Set the V Binning for the selected
SequencerIndex.
Binning Vertical Mode setting is applied in binning
mode.
Set the repeat count for the sequencer.
Displays the sequencer set number.
Set this to change the SequencerIndex.
(Enabled only for CommandSequencer.)
Specify the first index number to switch to when
starting [TriggerSequencerMode].
In [TriggerSequencerMode], reset the current index
number to the number configured in
[SequencerSetStart].