Param XBee A
XBee B
ST
—
—
D2/D3 —
ADC [2]
IR
—
1388
Note
The dash (—) in the table means to keep the default value. Do not change the default value.
Note
If you are using a Grove sensor and have connected it to the Grove AD2 connector, you must configure the D2 parameter as ADC [2] instead of the
D3.
3. Write the settings of all XBee modules with the Write radio settings button
XBee C
Effect
A
Defines the period of inactivity (no serial or RF data received) before going to sleep.
A (hexadecimal) = 10 (decimal) x 1 ms = 10 milliseconds.
ADC [2]
Sets the DIO2/AD2 or DIO3/AD3 pin as ADC in XBee B and XBee C, depending on if the XBee modules are
THT or SMT. This pin is connected to a potentiometer.
Configure the D2 parameter as ADC [2] only if the XBee module is surface-mount (SMT).
However, if the module is through-hole (THT), you have to configure the D3 parameter as ADC
[2] instead of the D2.
1388
Configures XBee B and XBee C to send IO samples every five seconds (5000 ms = 1388 in hexadecimal).
at the top of the Radio Configuration section.