Viewing Chassis Slot Information; Mounting The Switch - Alcatel-Lucent OmniSwitch 9800E Hardware User's Manual

Omniswitch 9000e series
Hide thumbs Also See for OmniSwitch 9800E:
Table of Contents

Advertisement

Chassis and Power Supplies

Viewing Chassis Slot Information

To view basic slot information via the CLI, enter the
-> show module
To view more detailed slot information, use the
-> show module long

Mounting the Switch

Important. Two people are required when lifting the chassis. Due to its weight, lifting the chassis unas-
sisted can cause personal injury. If you need to move the switch, be sure to power it down and remove all
modules and power supplies. For instructions on removing CMM or NI modules, refer to
"Network Interface (NI) Modules."
Power Supply" on page
Note. Due to their weight and airflow requirements, OmniSwitch 9000E Series switches cannot be wall-
mounted.
Airflow Considerations
Be sure that your switch is placed in a well-ventilated, static-free environment. Always allow adequate
clearance at the front and sides of the switch, as well as behind the switch's fan unit (located at the top-
rear of the chassis). The following top-view diagram shows recommended minimum clearances for
adequate airflow.
Note. Never obstruct the air intake vents located at the bottom-front and bottom-sides of the chassis or the
fan unit's air output vents located at the rear of the chassis. Clearance is not required at the top and bottom
of the chassis.
OmniSwitch 9000E Series Hardware Users Guide
show module long
For instructions on removing power supplies, refer to
2-27.
Chassis Top View
December 2008
show module
command at the CLI prompt:
form of this command. For example:
}
Rear. 6 inches minimum
at rear of chassis fan
unit.
Sides. 2 inches minimum
at left and right sides.
}
Front. 6 inches minimum
at front of chassis.
Mounting the Switch
Chapter 4,
"Removing a
page 2-9